TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR
PRODUCT WITH THE POWER CONNECTED. DON'T JUST UNSCREW
THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE
RECEPTACLE.
TROUBLE
PROBABLE CAUSE
Switch is off position
Motor does
not run.
Blown fuse
Tripped breaker
Plug disconnected
Corroded plug
Low water level
Thermal overcharge
Defective switch/float
Defective motor
Improper float position
Jammed impeller
Motor does
Plugged check valve
not deliver to
full capacity.
Blocked suction/inlet
Discharge leak
Blocked line/pipe
Worn impeller
Defective motor
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you've
purchased the pump, please contact us at 514 337-4415, and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.
6
FOR INFORMATION | TEL : 514.337.4415 | FAX : 514.337.4029
ACTION
Turn switch to on position
Replace
Reset
Re-install
Clean prongs
Add water and verify
Cool the motor
Replace
Replace/repair
Check movement
Clean
Clean/replace
Check for debris in pit and clean
Repair
Check for debris or ice
Repair/replace
Replace
6