Pompe pour bassin de lavage

Publicité

APPLICATION :
 This pump is designed for a permanent
installation to handle normal waste water
from domestic washing machines, bar
sinks located in basement play room, and
generally all waste water not containing
solids or materials which will clog the
impeller or switch operation, where the
waste or drain line is above the level
for gravity flow to sewer or septic bed
connections.
Capacity:
     
2'
1400 US GPH
4'
1200 US GPH
6'
1020 US GPH
We recommend that you install your pump in a clean and dry location where
STEP 1
there is adequate room for servicing at a later date. Protection from freezing
temparatures and good ventilation should be considered as well, to provide the
pump an environment for long life. Locate the pump directly under the stainer
of laundry tub or sink as per installation diagram (see page 4).
Friction loss in the discharge pipe must be taken into consideration when
many elbows and fittings are installed in the discharge line. Each elbows and
fittings must be considered as 1 feet of head.
Never run the pump dry. Damage to the seal may occur.
THE RUN OF THE PIPE FROM THE CHECK VALVE TO THE EXISTING
STEP 2
WASTE OR DRAIN LINE MUST NEVER BE SLOOPING DOWNWARD
EXCEPT WHEN CONNECTING TO SAME.
Using teflon tape, install the female portion of the union under the laundry tub
STEP 3
to the threaded male adaptor of the stainer and screw the male part of the
union, into the female pump intake. Then screw the union to hold the pump
securely in place.
From the pump discharge, run your length of 1 1/4'' discharge pipe,
STEP 4
using elbows and fittings, in your shortest possible run to the existing
waste or drain line. In the first vertical position of the piping, install the
supplied check valve.
From the check valve, continue to run your 1 1/2'' discharge pipe to the existing
STEP 5
waste or drain line.
Friction loss in
pipe not included.
8' 800 US GPH
10' 500 US GPH
INSTALLATION STEPS
see typical installation diagram in page 4
FEATURES :
 High performance noryl impeller.
 Full time connected run capacitor, to
eliminate starting wear vs regular motor.
 Thermal and overload protection.
 Flat union, check valve included.
 1/3HP, 115VAC, 60Hz, 4.0A.