Télécharger Imprimer la page

Burcam 300315WH Instructions D'installation page 12

Pompe pour bassin de lavage

Publicité

TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR
PRODUCT WITH THE POWER CONNECTED. DON'T JUST UNSCREW
THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM
THE RECEPTACLE.
TROUBLE
PROBABLE CAUSE
Switch is off position
Motor does
Blown fuse
not run.
Tripped breaker
Switch port clogged
Defective switch
Defective motor
Improper voltage
Motor runs
'P' trap between strainer
but no water
is delivered.
and pump
Improper voltage
Pump does
'P' trap between strainer
not deliver to
full capacity.
and pump
Air in suction line
Pump does
Missing check valve
not shut off.
Clogged check valve
in open position
Pump discharge too fast
Pump starts
on low head
and stop too
often.
Water pumped faster
than tub is filled
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you've
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.
ACTION
Turn switch to on position
Replace
Reset
Remove and clean switch, port, adaptor
Replace
Replace
Check voltage
Remove
Check voltage
Remove
Check for proper pipe slope to pump inlet
Install valve
Clean debris
Install ball valve in discharge line to
reduce flow rate
It is normal
6

Publicité

loading