Read and observe these instructions before using the device!
• Retain this operation and maintenance manual.
• Do only use the device for extracting dust and fume.
• Do not use the system for extracting burning or glowing substances!
Except FA10, FA20, WBA30
• Do not use the system for extracting inflammable or explosive gases.
• Do not use the system for extracting aggressive substances or aluminum dust.
• Do not use the system for extracting any liquids.
(Exception: OEN series)
• Protect the line cord from heat, moisture, oil and sharp edges.
• Pay attention to the admissible line voltage (cf. instructions on name plate).
• Use only original spare parts.
• Use only original filters.
• Do not operate the system without a filter element.
• Disconnect the device from the mains before opening it.
• The air outlet opening must not be covered or blocked.
• The device must always stand stable.
• Only the TBH crane eyes included in delivery may be used! Observe the enclosed short manual.
• In case of technical problems, contact the manufacturer or your specialist dealer!
When extracting carcinogenig substances or welding fume of material containing nickle or chrome, the regulations of
the German TRGS 560 „Luftrückführung beim Umgang mit krebserzeugenden Gefahrstoffen" or the respective local
regulation must be observed!
Personal protective equipment (PSA):
Observe local plant regulations.
• Respiratory protection: Half-mask as per FFP3 (EN149) (unless otherwise specified)
• Rubber gloves
• Safety goggles
• Depending on the nature of the hazardous substances, a protective suit should also be worn.
1.3
Usage According to Determination
LN, GL, BF, TFS and FP, FPV series extraction and filtration systems are designed to extract dust and fume and must not
be used for extracting burning or glowing substances, inflammable or explosive gases, aggressive substances and
aluminum dust and not for extracting liquids, as described in the safety instructions.
Special ATEX models may be used for extracting from Zone 22. However, correct connection of the system and all add-
on parts to a suitable grounding system must be provided. The device itself must not be opereated within a ATEX Zone.
OEN series devices may be used for extracting oil mist. For correct dimensioning, please call your TBH representative.
CR-LN and CR-GL series devices are suitable for punctual collection of dust emissions in cleanrooms and controlled
All manuals and user guides at all-guides.com
1 Safety instructions
52-236