Instructions for correct unit installation
GB
If the column of water between
the pump and the highest tap
exceeds.
15 mts. the unit cannot be
installed directly on the pump,
but is has to be raised until the
column of water between the
unit and the highest tap does not
exceed 15 mts. I.E. If column of
water is 20 mts.
From the pump, the unit must
be placed 5 mts. higher than the
pump.
The unit is equipped with a
check valve to prevent the
pipeline from losing pressure.
No taps can be installed
between the pump and
the unit.
PUMP'S PRESSURE
The unit is pre-set by the
manufactures at a restarting
pressure of 1,5 bar.
The pressure produced by the
pump must be normally 0,8 bar
higher than the pre-set pressure.
Before starting the unit check
suction and ensure that the pump
is primed.
8
It is advisable to connect the unit
outlet to the system by means of
a flexible hose.
Safety valve preventing water
emission in case of diaphragm
breaks
DO NOT TOUCH
It is imperative to install the unit
with the arrows in the upward
position.
The unit can be installed directly
on the pump, or between the
pump and the first tap.