Télécharger Imprimer la page

Camp Chef PG24ZD-2 Mode D'emploi page 9

Publicité

a "X" in front of the number when displaying the
"X" meat probe temperature and a "Y" for the "Y"
meat probe temperature. Example: "X155F"
Do not use meat probes when grill temperature
exceeds 350˚F. Damage to the probes may occur.
Do not allow meat probe wires to lie in the direct
heat zones (as shown by shaded areas).
Direct heat will damage the meat probe wires.
Always route the meat probes through ports on
the side of the grill. Do not submerge wire in
water. Not dishwasher safe.
CLEANING
Clean grates using a wire grill brush. This should
be done with each use. DO NOT use oven cleaner
or abrasive cleaners on the painted grill surfaces.
Use warm soapy water on all painted surfaces.
Clean grease pan, grease trough, and grease drain
tube occasionally. A spatula can be used to scrape
excess grease and a grill brush to brush clean. Do
not allow grease to build up on the grease tray or
in the grease trough as this can cause flare-ups
inside the grill. Make sure not to obstruct the
flow of grease off of the tray and into the grease
trough. Make sure not to block the airflow to the
temperature sensor on the left side of the grill.
TROUBLESHOOTING
GRILL DOES NOT TURN ON.
Grill fails to turn on after switching the power
button to the on position.
1. Make sure the grill is plugged into a powered
outlet. Check the circuit breaker and/or GFCI
switch. Test the outlet using another appliance.
2. Unplug the grill and check the fuse located in
CAUTION
the front panel. If the fuse is blown replace only
with 4.0 Amp 125V 5x20mm Fast Blow Fuse.
Typical fuse marking will be 4A125V, F4A125V,
4A250V, or F4A250V. Make sure to confirm they
are a Fast Blow Fuse. Actual fuse dimensions
are 5.2x20mm.
If problem cannot be resolved please call customer
service.
GRILL DOES NOT HEAT UP OR DIGITAL READOUT
DISPLAYS FLAME
1. Turn Power Off
2. Check hopper for pellets
3. Check firebox to see if there are pellets in the
firebox by removing the rack and heat deflectors.
Use a vacuum to clean-out any pellets that may
be in the bottom of the grill.
A. Try restarting the grill. If restarting the grill does
not work and pellets are getting to the burner
cup the heating rod may need to be replaced.
B. If there are few or no pellets in the burner then
turn the dial to the feed position and see if
pellets fall into the burner. If there are no pellets
check to see if the auger is turning. If the auger
motor is turning but the auger is not there may
be a sheared auger pin. You can determine if the
auger motor is turning by watching the small
white fan at the end of the auger motor under
the hopper. If the white fan is turning the auger
motor is on. If the white fan is turning and the
auger is not you will need to replace the auger
pin. If problem cannot be resolved please call
customer service
DIGITAL READOUT DISPLAYS SENSR
1. Turn the power off and unplug the grill.
2. Check to make sure the sensor inside of the grill
is connected properly to the electronic board
under the hopper.
3. Call customer service for a replacement sensor.
DIGITAL READOUT DISPLAYS PRERR
1. Press the Probe Temp button - Pressing the
Probe Temp button will toggle the digital
readout between the actual temperature inside
of the grill and the temperature measured using
the meat thermometer.
2. Make sure the meat thermometer is connected
properly to the front of the grill. If the Probe
Temp button is pressed to display the Probe

Publicité

loading