Problem and alarm code
The temperature of the water inside
the appliance is too high or malfunc‐
tion of the temperature sensor oc‐
curred.
The display shows i61 or i69.
Technical malfunction of the appli‐
ance.
The display shows iC0 or iC3.
The level of water inside the appli‐
ance is too high.
The display shows iF1.
The appliance stops and starts
more times during operation.
The programme lasts too long.
The displayed programme duration
is different than the duration in the
consumption values table.
The remaining time in the display in‐
creases and skips nearly to the end
of the programme duration.
Small leak from the appliance door.
The appliance door is difficult to
close.
The appliance door opens during
the wash cycle.
Rattling or knocking sounds from
the inside of the appliance.
The appliance trips the circuit-beak‐
er.
Once you have checked the appliance,
deactivate and activate the appliance. If the
problem occurs again, contact an Authorised
Service Centre.
22
ENGLISH
Possible cause and solution
•
Make sure that the temperature of the inlet water does not exceed
60°C.
•
Switch the appliance off and on.
•
Switch the appliance off and on.
•
Switch the appliance off and on.
•
Make sure that the filters are clean.
•
Make sure that the outlet hose is installed at the right height above the
floor. Refer to the installation instruction.
•
It is normal. It provides optimal cleaning results and energy savings.
•
If the delay start option is set, cancel the delay setting or wait for the
end of the countdown.
•
Activating options increases the programme duration.
•
The pressure and the temperature of the water, the variations of the
mains supply, the options, the quantity of dishes and the degree of soil
can change the programme duration.
•
This is not a defect. The appliance is working correctly.
•
The appliance is not levelled. Loosen or tighten the adjustable feet (if
applicable).
•
The appliance door is not centred on the tub. Adjust the rear foot (if ap‐
plicable).
•
The appliance is not levelled. Loosen or tighten the adjustable feet (if
applicable).
•
Parts of the tableware are protruding from the baskets.
•
The AirDry function is activated. You can deactivate the function. Refer
to Basic settings chapter.
•
The tableware is not properly arranged in the baskets. Refer to basket
loading leaflet.
•
Make sure that the spray arms can rotate freely.
•
The amperage is insufficient to supply simultaneously all the applian‐
ces in use. Check the socket amperage and the capacity of the meter
or turn off one of the appliances in use.
•
Internal electrical fault of the appliance. Contact an Authorised Service
Centre.