4 Operations
4.1 Light intensity
4.1.1 Range
• Dimming
4.1.2 Control
Remotely with DMX512-A protocol
Light output is the highest value of DMX512 command or local control
4.1.3 Parameters
Resolution (MODE):
Curve (LIGHT CURVE): Linear / Square
0%
DMX512-A
HTP mode (Highest Takes Precedence):
Focus mode: when standby screen displayed,
Push Exit → Light output = 100% for 1 minute
2x times Exit → Light output = 0%
Local control → via rotary knob
Mode
8 bits
16 bits
EN - 10 -
Locally via rotary knob
Resolution
255 steps – 1 DMX channel
65 535 steps – 2 DMX channels
EN
100%