Do not use the SpotLED at temperatures deviating from the specified ambient
temperature range.
Follow all instructions written on the equipment and as mentioned in this manual.
E
Repairs may only be carried out by the manufacturer or by a person appointed by the
manufacturer.
Modifications to the equipment or changes to the design are not permitted.
The product may only be used for the function for which it is designed and shall be
maintained in a good and clean condition.
If these instructions are not followed, the explosion safety of the equipment cannot be
guaranteed. The equipment could then endanger the life of the user and could cause the
ignition of an explosive atmosphere. Consequently, Artidor as the manufacturer will waive
any responsibility.
3.
Characteristics
The characteristics of the SpotLED can be summarized as follows:
Robust SpotLED with ingress protection level IP67
Light source: 5 PowerLEDs, 3 Watt each
780 Lumen
Coated aluminum housing, stainless steel bracket, powder coated
Available in two different housing colors
Obtainable in various beam angles with different optics
Provided with a fixed cable
Manufactured on the basis of the European Directive 2014/34/EU (ATEX 114)
Suitable for use in gas and dust hazardous areas classified as zone 2 and 22
Explosion safety category and protection degree against ignition applied:
II 3 G Ex ec IIC T4 Gc
II 3 D Ex tc IIIC T135˚ C Dc
Protection degree against the ingress of water and dust IP67 according EN 60529
Suitable for internal and external use
Rotation angle from -50˚ to +105º
4.
Application
The explosion-safe SpotLED series AR-040 have been designed for and are suitable for use
in hazardous classified areas due to flammable gases, vapors, mist, fibers and dust.
Because they are explosion-safe and certified on the basis of Group II Category 3GD of the
Installation manual AR-040 SpotLED
8 / 40
12-2024