Hook Mounting
20Nm
30
Optional: Bracket Mounting
12
Ø 15
64
Optional: Reflector Mounting
1 Nm
P1
Connect Power Cable
L
P
L
Brown
E
N
N
Blue
1.5-2.5 N.m
-
The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements .
-
Do not switch the luminaire on before completing installation.
-
The height between luminous surface and ground suggested be more than 5m; and the height between bottom of luminaire and mounting surface must be more than 0.3m.
-
If customer require the luminous surface levelness < 1°, pipe mounting method is recommended, and suggest to use gradienter to precisely measure and adjust.
-
If the external flexible cable or cord of this luminaire is damaged. It shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order
to avoid a hazard.
-
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
The corrosive atmosphere or hazardous materials such as sulfur, chlorine, phthalate, etc must be avoided during the use and storage.
-
-
Luminaire don't have any evaluation on additional protective measures to prevent luminaire from high-altitude falling and windproof structure, therefore it can't be used as
flood and tunnel luminaire.
-
Not suitable for use in harsh vibration and often causing vibration or swinging environment. Also not suitable for area prone to hurricane and extreme winds.
-
Installer needs to be arrange the Chain / Pipe for mounting. The default product is supplied with a mounting hook.
Do not stare at the operating light source.
-
For Indoor use only. This product is not suitable for cold storage areas lower than -20⁰C or areas where obvious temperature gradients are present, such as ventilation
opening, door, etc.
1
2
3
2x
4pcs
M4x10 Screw & D4 Cushion
25
8 12
Cable:
IEC
Max. x , mm
Ø .
Ø . mm
1.5-2.5 N.m
P
N
E L
0.8
0.1 Nm
Optional: Pipe Mounting
20 mm
G1/2"
2Nm
Safety string mounting
30
30Nm
17
20Nm
The hole (φ5 ) is for a safety string
Safety string has to be mounted for this luminaire.
Safety string is not provided by Signify, need to be prepared by user.
Remove 4 pcs nylon screws, use 4pcs M4x10 Screw & D4 Cushion to fix reflector.
Attention: 1. Reflector installation must be completed before steps of luminaire fixing and power
cable connection . 2. Please protect the diffuser during the steps of reflector installation.
Inrush current
Min.
x , mm
Imax (A)
Tref (µs)
P1
MCB
B-16 A
C-16 A
2/5
1
2
2Nm
I mains (A)
I max
max/2
Tref
BY101P
BY102P
BY100P
Electrical characteristics
42
40
650
600
Maximum number of luminaires
6
8
8
13
Ø12~14
G1/2
Pipe dimension
20Nm
30
I nom.
Time (us)
54
750
6
8