Fireplace operation in transitional periods
During the transitional periods (when external temperature exceeds 15° C), problems may be
encountered due to insufficient negative pressure (poor or no draught) in the chimney. In such a case,
try to achieve necessary draught by warming up the chimney. If this does not work, do not proceed
with the firing. Opening of a window or a door of the room during the firing might help to equalize the
internal and external air pressure.
Maintenance and cleaning
At the end of each heating season, clean the fireplace, fluepipes and chimney from soot deposits.
Regular inspection and cleaning are essential for preventing the risk of chimney fire. In case of
chimney fire, proceed as follows:
- never use water to extinguish the fire
- close all air supply passages to the fireplace and chimney
- having extinguished the fire, call the chimney sweeper to inspect the chimney
- call the manufacturer's authorised service to inspect the fireplace.
The door glass may be cleaned with ordinary window glass cleaners.
Should any problems occur during the operation (e.g. smoke), contact your chimney sweeper or the
closest local Service. Any repair/maintenance works on the fireplace shall be performed by
authorised service personnel and only original spare parts shall be used.
It's used for cleaning enamel and painted parts using soap and water, non-abrasive or chemically
non-aggressive detergents.
Warranty
The Manufacturer's warranty shall apply provided that the fireplace is used in accordance with these
Installation and Operating Instructions.
Space heating capacities
The total surface of heated space depends on the thermal isolation of the space and outside
temperature.
With 14 kW of heat power and dependent on external circumstances, it is possible to heat:
Occasional heating or intermittent heating should be considered as less favourable or even
unfavourable heating conditions.
Chimney dimensioning should be based on the following data:
Rated heating output
Flue gas flow rate [m]
Mean flue gas temperature downstream the flue connection
Minimum required negative pressure in the chimney [p] at rated output
Minimum required negative pressure in the chimney [p] at 0.8-times rated output
- under favourable conditions
- under less favourable conditions
- under unfavourable conditions
360 m³
240 m³
170 m³
25
14
kW
16,2
g/s
306
°C
0,12
mbar
0,10
mbar