5-3. Tipping
5-4. Preparing Unit For Operation
1
2
5
4
!
Do not move or operate unit
where it could tip.
!
Do not move unit by pulling
on extraction hose or equip-
ment may tip. Use handle on
fume extractor to move unit
!
Do not use this equipment to
support personnel, large
tools, or other material.
!
Do not use the fume extraction
equipment unless you are sure
it is correctly assembled and
working properly.
1
Connection Port
2
Collection Hose
6
3
Nozzle (Optional) − Not Shown
4
Caster w/Brake
5
Latch
6
115 Volt, 15 Amp AC Grounded
Receptacle
7
Input Power Plug
Insert the stub end of the collection
hose into the connection port. Be sure
the hose is securely installed.
7
Connect optional nozzle to other end
of collection hose.
Verify all eight latches are closed and
provide a secure attachment.
Lock caster brackets to keep fume
extractor in desired location.
Connect power cord to power supply.
A 115 volt AC, 15 amp individual
branch circuit protected by time delay
fuses or circuit breaker is required.
Select 12 AWG extension cord for
distances up to 50 ft (15 m) or 10
AWG extension cord for distances up
100 ft (30 m).