Télécharger Imprimer la page

Publicité

Liens rapides

OM-244 785E
2013−03
Processes
Multiprocess Welding
Description
Mobile Weld Fume Extractor
®
FILTAIR 130 Fume Extractor
File: Accessory
Visit our website at
www.MillerWelds.com

Publicité

loading

Sommaire des Matières pour Miller FILTAIR 130 Fume Extractor

  • Page 1 OM-244 785E 2013−03 Processes Multiprocess Welding Description Mobile Weld Fume Extractor ® FILTAIR 130 Fume Extractor File: Accessory Visit our website at www.MillerWelds.com...
  • Page 2 We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality.
  • Page 3 TABLE OF CONTENTS SECTION 1 − FUME EXTRACTION SAFETY PRECAUTIONS − READ BEFORE USING ....1-1. Fume Extraction Hazards ............. . SECTION 2 −...
  • Page 5 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING fume 2013−02 Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if Indicates special instructions.
  • Page 6 FALLING EQUIPMENT can injure. FIRE OR EXPLOSION hazard. D Use equipment of adequate capacity to lift and D Do not install or place unit on, over, or near support unit. combustible surfaces. D If using lift forks to move unit, be sure forks are D Do not install unit near flammables.
  • Page 7 D Do not use welder to thaw frozen pipes. FUMES AND GASES can be hazardous. D Remove stick electrode from holder or cut off welding wire at contact tip when not in use. Welding and cutting produces fumes and gases. D Wear oil-free protective garments such as leather gloves, heavy Breathing these fumes and gases can be hazardous shirt, cuffless trousers, high shoes, and a cap.
  • Page 8 1-4. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. BATTERY EXPLOSION can injure. D Do not install or place unit on, over, or near D Do not use welder to charge batteries or jump combustible surfaces. start vehicles unless the unit has a battery D Do not install unit near flammables.
  • Page 9 ARC WELDING AND PLASMA CUTTING can H.F. RADIATION can cause interference. cause interference. D High-frequency (H.F.) can interfere with radio D Electromagnetic energy can interfere with navigation, safety services, computers, and sensitive electronic equipment such as communications equipment. computers and computer-driven equipment D Have only qualified persons familiar with such as robots.
  • Page 10 SECTION 2 − MESURES DE SÉCURITÉ − EXTRACTION DES FUMÉES − À LIRE AVANT UTILISATION fume_2013−02_fre Se protéger et protéger les autres contre le risque de blessure — lisez, appliquez et rangez en lieu sûr ces consignes importantes de sécurité et d’utilisation. 2-1.
  • Page 11 D Lire et comprendre les instructions des fiches signalétiques et du Les PIÈCES MOBILES peuvent fabricant concernant les métaux, les consommables, les causer des blessures. revêtements, les nettoyants et les dégraisseurs. D L’extracteur de fumées doit être utilisé avec le bras d’extraction, D S’abstenir de toucher des organes mobiles tels les tuyaux, le filtre et les autres composants recommandés par le que des ventilateurs.
  • Page 12 D Ne pas enrouler les câbles autour du corps. D Portez un casque de soudage approuvé muni de verres filtrants D Si la pièce soudée doit être mise à la terre, le faire directement appropriés pour protéger visage et yeux contre les rayons et les avec un câble distinct.
  • Page 13 D Ne jamais placer une torche de soudage sur une bouteille à gaz. DES PIECES DE METAL ou DES D Une électrode de soudage ne doit jamais entrer en contact avec SALETES peuvent provoquer des une bouteille. blessures dans les yeux. D Ne jamais souder une bouteille pressurisée −...
  • Page 14 D Tenir l’équipement (câbles et cordons) à distance des véhicules Les PIÈCES MOBILES peuvent mobiles lors de toute opération en hauteur. causer des blessures. D Suivre les consignes du Manuel des applications pour l’équation D S’abstenir de toucher des organes mobiles tels de levage NIOSH révisée (Publication Nº94–110) lors du levage manuelle de pièces ou équipements lourds.
  • Page 15 LE SOUDAGE À L’ARC ET LE RAYONNEMENT HAUTE COUPAGE PLASMA risquent de FRÉQUENCE (H.F.) risque provoquer des interférences. provoquer des interférences. D Le rayonnement haute fréquence (H.F.) peut D L’énergie électromagnétique peut gêner le provoquer des interférences avec les équi- fonctionnement d’appareils électroniques sen- pements de radio−navigation et de com- sibles comme des ordinateurs et des équi-...
  • Page 17 SECTION 3 − DEFINITIONS 3-1. Symbols And Definitions Protective Earth Percent (Ground) Amperes Volts Filter SECTION 4 − SPECIFICATIONS 4-1. General Description The Filtair High Vac 130 weld fume collector is a mobile, high-vacuum/low volume system that uses a high efficiency cartridge filter to collect airborne weld fume particles.
  • Page 18 SECTION 5 − INSTALLATION 5-1. Serial Number And Rating Label Location The serial number and rating information is located on the back of the unit. Use rating label to determine input power requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual. 5-2.
  • Page 19 5-3. Tipping Do not move or operate unit where it could tip. Do not move unit by pulling on extraction hose or equip- ment may tip. Use handle on fume extractor to move unit Do not use this equipment to support personnel, large tools, or other material.
  • Page 20 SECTION 6 − OPERATION 6-1. Controls Only use the fume extractor to extract weld fumes. Do not use the fume extractor to extract hot gases (above 140° F/60° C), wood or cement dust, engine ex- haust, liquid vapors, explosive materials, aggressive fumes (acid), fumes from burning ob- jects, or fumes from cleaning, cutting,...
  • Page 21 6-2. Prestart Checklist (Before Welding) Do not use the fume extrac- tion equipment unless you are sure it is correctly as- sembled and working prop- erly. Check for free and easy move- ment of the collection hose and nozzle before each use. Clean Air Outlet Verify clean air outlet is not ob- structed and discharge air appears...
  • Page 22 7-2. Servicing Filter Turn off power and disconnect input power cord. Do not operate unit without filter or with dirty filter. Do not breathe the particles collected by the fume extractor. Wear approved safety equipment (respirator, gloves, long sleeve shirt) when servicing fil- ter and spark guard.
  • Page 23 7-3. Servicing Motor Brushes Motor Brushes Sight Windows Motor Brush Release Tabs Carbon brushes in the motor will wear. The expected life is approxi- mately 600 working hour. We recom- Top View − Cover Removed mend replacing the carbon brushes regularly to ensure proper operation of the unit, or when the end of either brush is visible in the sight window.
  • Page 24 7-4. Overload Protection Fuse Holder block Fuse F1 (See Parts List) Spare Fuse When a circuit breaker or fuse opens, it usually indicates a Top View − Cover Removed more serious problems exists. Contact a Factory Authorized Service Agent. Fuse F1 protects the blower motor from overload.
  • Page 25 SECTION 8 − TROUBLESHOOTING 8-1. Troubleshooting Table Trouble Remedy Motor/blower will not start or continue Check input power connection. running. Check fuse F1, and replace if open (see Section 7-4) Check motor brushes (see Section 7-3). Have Factory Authorized Service Agent check unit. Air flow cannot be adjusted.
  • Page 26 SECTION 9 − ELECTRICAL DIAGRAM 245 477-A Figure 9-1. Circuit Diagram OM-244 785 Page 22...
  • Page 27 Notes Work like a Pro! Pros weld and cut safely. Read the safety rules at the beginning of this manual. OM-244 785 Page 23...
  • Page 28 SECTION 10 − PARTS LIST Hardware is common and not available unless listed. 245 354 Figure 10-1. Main Assembly OM-244 785 Page 24...
  • Page 29 Item Dia. Part Mkgs. Description Quantity Figure 10-1. Main Assembly ......Nameplate (Order By Model And Serial No.) .
  • Page 30 Notes TM-216 869 Page 26 Dynasty 350/700, Maxstar 350/700...
  • Page 31 Effective January 1, 2013 (Equipment with a serial number preface of MD or newer) This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or warranties expressed or implied. Warranty Questions? LIMITED WARRANTY − Subject to the terms and conditions below, 6 Months —...
  • Page 32 Contact the Delivering Carrier to: File a claim for loss or damage during shipment. For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department. © ORIGINAL INSTRUCTIONS − PRINTED IN USA 2013 Miller Electric Mfg. Co. 2013−01...