INSTALLATION
SAFETY NOTICE
• IF THIS STOVE IS NOT PROPERLY INSTALLED,
A HOUSE FIRE MAY RESULT. TO REDUCE THE
RISK OF FIRE, FOLLOW THE INSTALLATION
INSTRUCTIONS.
• CONSULT
YOUR
DEPARTMENT OR FIRE OFFICIALS ABOUT
PERMITS, RESTRICTIONS AND INSTALLATIONS
REQUIREMENTS IN YOUR AREA.
• USE SMOKE DETECTORS IN THE ROOM WHERE
YOUR STOVE IS INSTALLED.
• KEEP FURNITURE AND DRAPES WELL AWAY
FROM THE STOVE.
• NEVER
USE
GASOLINE,
LANTERN
FUEL,
LIGHTER FLUID, OR SIMILAR LIQUIDS TO START
OR "FRESHEN UP" A FIRE IN THIS HEATER.
KEEP ALL SUCH LIQUIDS WELL AWAY FROM
THE HEATER WHILE IT IS IN USE.
• IN THE EVENT OF A CHIMNEY FIRE, TURN THE
AIR CONTROLS TO THE CLOSED POSITION,
LEAVE THE BUILDING AND CALL THE FIRE
DEPARTMENT IMMEDIATELY!
• DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
• A SOURCE OF FRESH AIR INTO THE ROOM OR
SPACE HEATED SHALL BE PROVIDED WHEN
REQUIRED.
• DO NOT INSTALL THIS APPLIANCE IN A MOBILE
HOME, MANUFACTURED HOME, TRAILER OR
TENT (NO EXCEPTIONS PER HUD FEDERAL
STANDARD: 24 CFR CH.XX).
WARNING:
VERIFY THAT THE APPLIANCE IS PROPERLY
INSTALLED BEFORE FIRING FOR THE FIRST
TIME. THIS APPLIANCE SHOULD BE INSTALLED
BY A QUALIFIED INSTALLER TO ENSURE A
CORRECT AND SAFE INSTALLATION. NEVER USE
TEMPORARY OR MAKESHIFT COMPROMISES
DURING THE INSTALLATION.
WARNING:
PROVIDE ADEQUATE COMBUSTION AIR TO THE
ROOM WHERE THE APPLIANCE IS INSTALLED.
RESTRICTING COMBUSTION AIR WILL RESULT IN
A LAZY FIRE WHICH CAUSES SOOT OR CREOSOTE
BUILDUP AND GREATLY REDUCES EFFICIENCY.
All manuals and user guides at all-guides.com
MUNICIPAL
BUILDING
GASOLINE-TYPE
KEROSENE,
CHARCOAL
DO NOT CONNECT A WOOD BURNING APPLIANCE
TO AN ALUMINUM TYPE B GAS VENT. THIS IS
NOT SAFE. USE APPROVED MASONRY OR A UL
103 HT (U.S.) LISTED RESIDENTIAL TYPE AND
BUILDING HEATING APPLIANCE CHIMNEY. USE A
6" DIAMETER CHIMNEY, THAT IS HIGH ENOUGH
TO CREATE SUFFICIENT DRAFT.
US Stove highly recommends your stove be installed by a
qualified NFI (US) or WETT (Canada) technician. To find
the nearest qualified installer, go to:
https://nficertified.org,
https://www.wettinc.ca/
FLOOR PROTECTOR
A solid non-combustible floor, concrete or solid masonry,
must extend 6" (153 mm) to either side of the body of the
appliance and 17" (432 mm) in front of the face of the
appliance. When combustible flooring falls within these
minimum dimensions, it must be covered with a listed
floor protector, with an R-Value of at least 1.4. Check local
building codes if you want to finish the floor covering with
grouted ceramic floor tile.
Minimum Floor Protector Specifications
A
B
38" U.S.A.
C
* = Canadian installations
requires 8" (204 mm)
5
© 2021 United States Stove Company
WARNING:
B
A
FLOOR PROTECTOR
C
17"
432 mm
*6"
*153 mm
966 mm
42" CAN.
1067 mm