15) Electrical and mechanical features
Dimensions and Weight of card: 170 x 70 x 46 mm - 0,2 Kg
Power transformer: 230/20Vac 100VA
Stand-by power consumption: 1 W about
Working temperature: from 0 to + 60 °C (inside)
Motors power supply: 24 Vdc - 80 W max (total)
Blinker power supply: 24Vdc - 5 W max
Accessory power supply: 12 Vdc 3 W max
Battery charger capacity: 0,1 A
Relay contact capacity: 30 A
Amperometric Stop regulation: from 50 to 87%
Programming of motor work time: 60 seconds max
Programming of delay in opening M1: 300 seconds max
Programming of delay in closing M2: 300 seconds max
Programming of pause time: 300 seconds max
Operating frequency: 433,92 or 868,35 MHz
Warning: The unit must not be switched on if the connected loads or the power supply exceed the a.m. limits. Failure to observe this precaution can
result in damage to people, animals or objects for which the manufacturer cannot be held responsible.
16) Electric connections
Terminal board J4
Terminal 1 - Aerial cable connection (signal)
Terminal 2 - Aerial cable connection (shield)
Faston FS1 - 20 Vac power coming from the electric transformer
Faston FS2 - 20 Vac power coming from the electric transformer
Faston FS3 - Positive pole connection of buffer battery
Faston FS4 - Negative pole connection of buffer battery
Important: Make sure of the correct positioning of the jumper JP1 - page 21
Terminal board J1
Terminal 1 - Electric contact N.O. of start button
Terminal 2 - Common power supply for all electric contacts
Terminal 3 - Electric contact N.C. of stop button
Terminal 4 - Electric contact N.C. of the photostop
Terminal 5 - Common power supply for all electric contacts
Important: The normally closed inputs not in use must be fitted with jumpers.