Télécharger Imprimer la page

Elica PCHBL630SS Guide D'utilisation, D'entretien Et D'installation page 8

Publicité

Install Range Hood
1 Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
B
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
1
2 Mark with a pencil the lower mounting holes location.
3 Uninstall the hood assembly, and drill 3⁄16" (4.8 mm) pilot
holes at marked locations.
4 Hang the range hood again on 2 upper mounting screws.
5 Level the range hood and tighten upper mounting screws.
6 Install 2 - 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
Electrical Connection
WARNING
ELECTRICAL SHOCK HAZARD.
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1 Disconnect power.
2 Remove terminal box cover.
3 Remove the knockout in the terminal box cover and install
a UL listed or CSA approved 1⁄2" strain relief.
4 Run home power supply cable through strain relief, into
terminal box.
8
Connect Vent System
1 Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
1 Fit vent system over the exhaust outlet.
2 Measure from the bottom of the air deflector to the bottom of
the hood outlet. Cut the ductwork at the measured dimension.
3 Seal connection with clamps.
4 Check that back draft dampers work properly.
E
D
C
B
A
A. UL listed cable connectors
B. White cables
C. Black cables
5 Use UL listed wire connectors and connect black wires
(C) together.
6 Use UL listed wire connectors and connect white wires (E)
together.
WARNING
ELECTRICAL SHOCK HAZARD.
A
B
Roof outlet
Wall
outlet
Dimension
to measure
D. Green (or bare) and yellow-green ground
wires
E. Household power cable

Publicité

loading

Ce manuel est également adapté pour:

Pchbl636ss