Télécharger Imprimer la page

OBI B-TPS 19500/E Notice Originale page 20

Publicité

GB
• If the power cable is damaged immediately dis-
connect the plug. Never use the device if the
power cable is damaged.
• If the device is not in use make sure the plug is
pulled out.
• Make sure that the device is switched off before
plugging in the mains cable.
• Make sure that the device is switched off before
unplugging it.
• Disconnect the power supply before transporting
the device.
• If the power connection cable of this device is
damaged, it must be replaced by the manufac-
turer or the manufacturer's customer service
department or a similarly qualified person in order
to prevent risks.
Device-specific safety instructions
• The cutting or modification of the power cable is
not permitted and will void the guarantee!
• Extension cables must not be used.
• Disconnect the mains plug before all work on the
appliance.
• Do not install and switch on the appliance if there
are people or animals in the medium being
pumped (e. g. a swimming pool), or they are in
contact with it.
• Children and young people under the age of 16
years must not use this appliance, and must be
kept away from it when it is in operation.
• Do not leave the unit unattended. If leaving it for
any period of time, unplug.
• Repairs must be carried out only by a qualified
electrician. If repairs are carried out incorrectly,
there is a danger of liquid penetrating into the
electrical components of the appliance.
• Symbols affixed to your tools may not be removed
or covered. Information on the device that is no
longer legible must be replaced immediately.
Read and observe the operating instruc-
tions before commissioning.
Your appliance at a glance
Note: The actual appearance of your
device may differ from the illustrations.
► P. 3, fig. 1
1. Carrying handle
2. Mains cable and plug
3. Hose adapter for pressure connection
4. Elbow
5. Suction openings
6. Float switch
7. Float switch height adjustment
What is included
• Submersible pump
• Instructions for use
20
Operation
Installation and commissioning
Attach a sufficiently long and strong rope to the han-
dle before first use. The pump is submerged into the
liquid on this holding rope and can also be carried
with it as well as with the handle.
Note: In the case of continuous use of the
pump with the rope, the condition of the
rope must be checked regularly as it can
decay and break over time.
Connect pressure pipe
Hose diame-
13 mm
ter
(½")
15 mm
(⅝")
19 mm
(¾")
Hose connections of the universal adapter
A
A
B
Hose con-
Discon-
nection
nect top-
most hose
connection
at [A].
Note: The maximum delivery quantity per
hour is achieved using a 50 mm (2")
hose.
The actual conveyance volume depends
on the delivery height and the hose used.
The volume may be reduced by more
than 50% if a smaller hose is used.
The use of rigid pipes with a non-return valve is rec-
ommended for use at a fixed location. This prevents
return flow of the liquid when switching off.
NOTICE! Risk of damage to the appli-
ance! Only tighten the hose adapter by
hand during mounting! Overtightening the
adapter damages the thread.
– Screw pressure line onto the pressure connec-
tion.
– When using a hose, screw the hose adapter onto
the pressure connection.
– Push the hose firmly onto the hose adapter and
secure with a hose clamp.
25 mm (1") 38 mm
(1½")
B
Do not dis-
Discon-
connect
nect both
any hose
upper hose
connec-
connec-
tion.
tions
at [B].