Trouble
Trouble
indication
Indicator Digit
Yellow LED
08
– 8 Flashes
Yellow LED -
09
9 Flashes
Yellow LED
0C
– 12 Flashes
All LEDs
flashing
N/A
together
Red and
Yellow LEDs
N/A
flashing
together
Only Green
LEDs
N/A
flashing
Green LEDs
N/A
alternating
Possible
Causes
Receiver
Thistroubleisindicated whensupervision isenabled andtheunit
l
Supervision
isnotable tosuccessfully communicate with thereceiver.
Ifthistrouble persists,contactthe centralstation.
Trouble
l
Theunithasexhausted allcommunications attemptstoall
l
FTC Trouble
programmed receivers for events generated by the communicator.
Restartthe system,iftroublepersists,contactthedealer.
l
This indication appears when section [021] system account code
Module
l
or sections [101],[111],[201],and [211]receiver accountcode
Configuration
have notbeen programmed. Ensure thata valid accountcode has
Trouble
been entered in these sections.
Boot Loader
Disconnect power, then reconnect power to the communicator
l
module.
Failed
The unitisstillinitializing, please waitwhile theunitgetsits
l
Initialization
programmingandestablishes aconnection toall programmed
Sequence
receivers.
NOTE: This process may take several minutes to complete.
Hardware Default
Thehardware defaultjumperisinstalled andmustbe removed.
l
See Figure 3.
Jumper
Radio Reset or
Ifthisstatuspersistsand the yellow LEDshows5 flashes,confirm
l
Radio
thatthe SIM card is active.
Initialization
Trouble Possible Solution