ERROR CODES
--OL--
Overload
--UL--
Under Load
Err 4
Zero Setting Error
Err 6
A/D out of range
Err 19
Initialize Zero Error
fai l
Calibration Error
Ba lo
Battery Low
19 OF 59
ERROR CODES
DESCRIPTION
1-800-295-5510
uline.com
RESOLUTION
Remove weight from the scale.
If the problem persists, contact Uline Customer
Service at 1-800-295-5510.
Minus weight, check the platform and restart
or calibrate.
The scale was outside the normal zero setting
range either when it was turned on or when
the ZERO key was pressed.
Remove weight from the scale and try again.
Use the TARE key to set the display to zero
value.
If the problem persists, contact Uline Customer
Service at 1-800-295-5510.
The values from the A/D converter are outside
the normal range. Remove weight from the
scale if overloaded, make sure fork cover
plate is attached.
Indicates the load cell or the electronics may
be faulty.
If the problem persists, contact Uline Customer
Service at 1-800-295-5510.
Calibrate the scale.
Check the test weights and recalibrate.
Recharge the battery, check the voltages.
1024 IH-11553