Télécharger Imprimer la page

Lux Tools D-MHA-9 Set Notice Originale page 26

Publicité

GB
5. Hose connection
6. Setting screw for air flow
Supplied as standard
• Instructions for use
• Chipping hammer
• Retaining spring
• Chisel (5×)
• Plug-in coupling
• Lubricating oil
Operation
Check before switching on!
Check the safe condition of the product:
• Check whether there are any visible
defects.
• Check all parts to make sure that they fit
tightly.
• Check whether pressure has built up in
the compressed air system.
• Check whether the compress air connec-
tion and the pressure pipes are tight.
Compressed air supply
NOTICE! Risk of product damage! 
Only operate the device with cleaned,
condensate-free and oil-atomised
compressed air.
• Fittings and hoses must be designed in
accordance with the pressure and the
required air quantity.
• Always use a compressed air mainte-
nance unit with a filter pressure reducer
and oil-mist lubricator.
– Remove the protective cap (7) (► P. 3, 
fig. 2).
– Screw the plug-in coupling (8) into the
hose connection (5) (► P. 3, fig. 3).
– Plug the compressed air hose into the
plug-in coupling and allow to engage
firmly (► P. 3, fig. 4).
Mount the retaining spring
► P. 4, fig. 5
DANGER! Risk of injury! The
retainer spring prevents the inde-
pendent loosening of the tool from the
device.
Do not operate the product without
retaining spring!
26
DANGER! Risk of injury! Before all
work on the device, disconnect the
compressed air supply.
– Screw the retaining spring (1) to the
device as depicted.
Insert the tool
► P. 4, fig. 6
DANGER! Risk of injury! Before all
work on the device, disconnect the
compressed air supply.
– Bend the front bracket of the retaining
spring (1) as depicted and hold.
– Push the tool (9) into the tool mount as far
as it will go and release the retaining
spring (1).
Chipping
– Make sure that the setting screw (6) is
fully open.
– Apply light pressure to the device to pre-
vent the device from making uncontrolled
movements.
– Switching on: Press the On-Off switch (4).
– Switching off: Release On-Off switch (4).
Note: Strong pressure on the device
does not increase efficiency.
Cleaning and maintenance
Cleaning and maintenance at a glance
Regularly, depending on the conditions of 
use
What?
Clean the product.
Every 50 operating hours or every 3 
months 
(more often when operating in dusty envi-
ronments)
What?
Lubricate the de-
vice.
Maintenance
Fill with oil
DANGER! Risk of injury! Before all
work on the device, disconnect the
compressed air supply.
Note: For direct lubrication of the
device or for addition to the com-
pressed air maintenance unit we rec-
ommend motor oil SAE 10 or SAE 20.
How?
Wipe the device with
a slightly damp cloth.
How?
► Fill with oil – p. 26