Télécharger Imprimer la page

Elitech Glog 5 Instructions page 3

Publicité

Product presentation
LCD display
① Work status
② Function Description
⑥ Light and vibration alarm signs
⑤ Battery level
*Note: To ensure data reliability, please do not enable recording when the battery level is less than or equal to 20% (
and
20%)
Selection table
(standard light and vibration sensors)
Model
Probe type
Built in temperature
Measuring range
Accuracy
Technical parameter
Vibration range
Range of illumination intensity
Resolving power
Key
Indicator light
Display
Positioning method
Storage capacity
Shadow data
Record interval
Upload interval
Data upload method
Freight initiation method
Freight stopping method
Repeat startup
Flight Mode
Alarm Mode
Battery type
OTA upgrade
Waterproof grade
Work environment
Storage environment
Specification and size
Battery life
Shelf life
Technical parameter
1.Add device
Login platform website: http://www.i-elitech.com, or scan the code to download and install the APP .
Register, log in, and add devices according to the prompts.
2.Activation
Press and hold the
normally, indicating that the device has been activated.
Note: Clicking on the button and the screen displaying normally indicates that the device has been activated;
3.Start Record
Press and hold the
If the
indicator flashes, it will enter a delayed countdown state, and after the delay ends, it will automatically start
recording;
4.Stop recording
Press and hold the
display a
sign indicating that the recording has been
successfully stopped;
5.Data export
The device is connected to the computer USB interface through a data cable and will automatically generate PDF+CSV
format data reports. You can copy the generated report to your computer for saving.
Note: The keys are invalid during the data export process
6.Flight Mode
Enable: Press and hold the
screen will display a
mode has been successfully activated;
Close: Press and hold the
icon disappears, it indicates that the airplane mode has
been turned o ;
Note: To enable and disable other flight modes, please operate through the platform or app.
Freight Management Operation Instructions
1. After logging into the platform or app, click on the 'Freight Management' menu in the main menu;
2. Click on the 'Configuration' menu on the homepage, and sequentially create and add 'User Management', 'Carrier',
'Location', 'Alarm Presets', and' Freight Template ';
3. Click on the 'Freight Management' menu on the homepage to create and manage freight;
Note: For detailed operation manuals, please refer to the operating instructions on the platform or APP;
LED indicator light description
Equipment status/operation
Fault, low battery (below 5%)
Not configured
Not active
Not started
Start Record
Start delay/timing
In the records
Stop recording
Stopped
Report generation in progress
USB connection in progress
Clear report flag
Communication abnormality
Enter flight mode
Exit flight mode
LCD display instructions
Data not uploaded, unable to activate
Safety instructions and precautions
1. Safety instructions
To ensure that you install and use this product correctly, please read and strictly comply with the following terms:
Battery:
Please use the original battery and do not use other batteries to prevent damage to the equipment or other malfunctions.
Do not disassemble, squeeze, hit, or heat the battery privately, and do not place it in a fire, otherwise it may cause battery
explosion and fire.
Equipment:
Do not use this equipment in flammable and explosive gas environments, otherwise it may cause explosions or fires.
During the use of the equipment, if the equipment emits a burnt or other odor, the power supply should be immediately
cut o and the manufacturer or supplier should be contacted in a timely manner.
2. Precautions and maintenance requirements:
If the equipment is not used for a long time, it should be removed and stored in a dry and cool environment in the
packaging box.
Users are not allowed to make any unauthorized changes to this device. Any unauthorized changes may a ect the
accuracy of the device or even damage it.
Do not place the device outdoors for use to avoid instrument short circuits, burns, and other malfunctions caused by
adverse weather conditions such as rain and lightning.
When the recorder is o ine (no data upload), please confirm the networking status of the device;
Please use within the measurement range of the recorder
Please do not forcefully impact this recorder
Sensors should be calibrated regularly to ensure their accuracy meets usage requirements
The measured values of the recorder may be a ected by the following factors:
Temperature error:
The stable time in the measurement environment is too short;
Close to heat sources, cold sources, or directly exposed to sunlight;
Humidity error:
The stable time in the measurement environment is too short;
Long term exposure to steam, water mist, water curtains, or condensation environments;
Contaminated:
Being in a dusty or other polluted environment
If the sensor is found to be blocked or contaminated, it should be wiped with a dust-free cloth dipped in clean water. It
is strictly prohibited to use high molecular weight chemical solvents such as alcohol for wiping.
If scrapped, it must be strictly handled in accordance with the "Regulations on the Management of Recycling and
Disposal of Waste Electrical and Electronic Products".
Glog 5 T
Glog 5 TH
Built in temperature
and humidity
-30℃~70℃
-30℃~70℃
0%RH~100%RH
±0.5℃
±0.5℃
±5%RH
0g~16g
0~52000Lux
0.1°C/0.1%RH/0.1g/1Lux
Double button design
Red and green, red and blue LED indicator lights
Broken code display screen
LBS+GPS (optional)
60000 (pre shadow data) 32000 (normal recording+rear shadow data)
Front+Rear
1min~24h; Default: 5 minutes
1min~24h adjustable Default: 60 minutes
4G+2G
Button, platform, timer
Button, platform, full memory
3 times (within the shelf life)
Button, timer, electronic fence
Overlimit and low battery
3.0V disposable lithium manganese battery 4800mAh (CR14505 3B6H)
Upgrades can be made through data management software and platforms
IP65 (built-in)
-30 ℃~70℃, 0% RH~100% RH (non condensing)
15~30℃,20~75%RH
103 x 61.3 x 30 (mm)
Record once every 5 minutes in a 25 ℃ environment, upload every 30 minutes, and use the
temperature and humidity recorder for a total of 60 days;
(Usage time+Storage time) 1 year
button for 5s, and the screen will display
button for 5s, and the screen will display a
button for 5s, and the screen will
Device
button for 5s, and the
symbol indicating that the airplane
button for 5s. If the screen
LED display
No display
Blink twice simultaneously
Blink twice simultaneously
Flashing once at the same time
Flashing 5 times
Flashing alternately once
Flashing once (normal)
Flashing once (alarm)
Flashing 5 times
Flashing twice (normal)
Flashing twice (alarm)
Flashing alternately once
Chang Liang
Simultaneously flashing
Flashing 3 times simultaneously
Flashing 5 times
Flashing 5 times
Record
Low battery
① Back mounted hanging hole
③ LED indicator light
⑤ Serial number
⑦ Power supply+data interface
⑨ Activate/Flight Mode Button
③ ④ ⑤
③ Flight mode
⑥ Time and number of records
Glog 5 TE
External
temperature+internal
temperature
-40℃~85℃
±0.5℃
symbol, indicating successful startup recording;
Connection to computer
during report generation
Points without uploading points
② LCD display screen
④ Start stop button
⑥ Light sensor
⑧ Built in sensors
⑩ External sensor
④ Signal status
⑧ Temperature and humidity values
Glog 5 THE
External temperature
and humidity+inter-
temperature+internal
nal temperature
External: -40℃~85℃
0%RH~100%RH
built-in: -30℃~70℃
±0.5℃
±5%RH
Trigger method
Short press the button
Short press the button
Short press the button
Short press the button
Long press the right button for 5s
Button/10s automatic flashing
Long press and right-click for 5s
Short press the button
/
Connect to USB
Long press the left button for 5s (USB connected)
Flashing during network connection
Long press the left button for 5s
Long press the left button for 5s
Usage times used
Probe malfunction
between
10%
Glog 5 TLE
External ultra-low
temperature
External: -200℃~
150℃
built-in: -30℃~70℃
±0.5℃(-40℃~85℃)
±1℃(-100℃~150℃)
± 2 ℃ (other)

Publicité

loading