SWIMMING POOL HEAT PUMP TYPE SP
Controller interface diagram and definition
WWW.NORSUP.EU
Alterations which serve the technological progress as well as errors excepted!
SWIMMING POOL HEAT PUMP TYPE SP
Main board of the input and output interface instructions below
Number
Sign
Meanin g
01
P10-1/2/3(U/V/W)
Compressor
02
P13(L)
Resistance
03
P14(L)
Resistance
04
CN97
DC motor
05
RS485-2
The port for centralized control
06
RS485
Color line controller communication
07
OT
Water output temperature
08
ET
System exhaust temperature
09
IT
Water input temperature
10
SUT
System suction temperature
11
CT
System fan coil temperature
12
AT
Ambien t temperature
13
HP
System high pressur e
14
LP
System low pressur e
15
FS
Water flow switch
16
MODE
Mode switch
17
REMOTE
Emergency switch
18
CN11
4-way value
19
CN18
Water pump
20
CN13
Reserved
21
CN66
Compressor signal
22
CN99
Low pres sure sensor
23
CN15
Electronic expansion valve
24
CN10
Program download interface
25
P1
Live wire
26
P2
Neutral wire
27
P00
Grounding
Alterations which serve the technological progress as well as errors excepted!