18
Hearth Installation
Poêle
REMARQUE:
Ce type d'installation
nécessite un
regarnissage complet
(connexion positive).
© Travis Industries
Stove Installation
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation. The
chimney must be 15' to 33' tall.
Combustible
Mantle
Floor Protection
(See the section
"Floor Protection
Requirements"
for more details)
(for qualified installers only)
Min. 36"
100-01282
Cap and flashing
prevents water from
entering
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Airtight Insulated
Clean-Out
Remove damper
or wire it open
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
4150526