4 .
When the burner is lit in the low position (small flame), stop pressing the ignition button and
holding
the control knob for no more than 15 seconds to heat the thermocouple (FSD); then release it (the
first ignition usually takes longer, because the gas circuit is full of air).
5. If the burner does not stay lit, wait 1-2 minutes and then repeat steps 3 and 4.
6. The burner is now lit in the Minimum position (small flame).
7. You can adjust the height of the flame by turning the knob from the Minimum position (small flame) to
the Maximum position.
8. In case of accidental flame interruption (due to wind or other reasons), the thermocouple will
automatically cut off the gas supply within a maximum of 60 seconds.
Note: The burner may make noise when initially ignited.
If you experience any ignition problems, refer to the "Troubleshooting" section.
TURN OFF THE GAS HEATER
Turn the control knob to the PILOT position.
1.
2 . Press and turn the control knob to the off position.
3. Close the gas flow of the bottle regulator.
IMPORTANT: To turn off the cooker completely, it must always be shut off at the gas regulator on the
cylinder.
GAS REQUIREMENTS
o Only use the type of gas and type of LPG cylinder specified by the manufacturer.
o The appliance must use an approved gas regulator (approved for a working temperature of not less
than 50 ˚C) according to Standard EN16129 (inlet and outlet connection of the gas regulator.
|