4. Technical data
Order Type
Supply voltage
Battery life
Temperature setting range
Temperature resolution
Switching current
Output
Output signal
Timing resolution
Accuracy of clock
Ambient temperature
Rated impulse voltage
Ball pressure test temperature
Voltage and Current for the for
purposes of interfernce measurements 230 V, 0,1A
Safety class
Degree of protection
Software class
Degree of pollution
Weight (with batteries)
Energy class
(acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
54
E200
2 x AA 1,5 V alkaline batteries
3 years (typically)
7 °C to 32 °C
0,1 °C (setting and display)
max. 8(2)A; AC 24 ... 230 V~
Relay change over contact, voltage free
PID with PWM (pulse width modulation) or
ON/OFF selectable
1 minute
< 4 Min / year
Operating
0 °C to 40 °C not condensing
Storage
–20 °C to 85 °C not condensing
4 kV
75 ± 2 °C
II (see Caution, page 46)
IP 30
A
2
~ 300 g
IV = 2 %