840138401_ENv01.qxd:Shaver_blender_env03
Preparation
Setting up the Unit
The Ice Shaver/Blender must be placed on a
sturdy, level surface. It is recommended that it be
located near a sink or other drain location.
Leveling the Unit
For proper operation and drainage, the unit must
be level. Loosen the jam nuts and turn the leveling
feet (clockwise to lower a corner, counterclockwise
to raise a corner) until the unit is level and all four
leveling feet are in solid contact with the
countertop. Once the unit is level, tighten the jam
nuts to lock the feet at the desired height.
Drain Hose
The end of the drain hose should drain into a sink,
drain, or bucket. To ensure proper drainage, the
outlet end of the drain hose must be lower than the
fitting end, and there should be no kinks or pinch
points in the hose. If a tight bend is needed, such
as at the edge of a countertop, use an elbow fitting
and hose clamps (not included) to make the bend.
Preparing for Use
Before plugging in the unit for the first time, the ice
hopper should be sanitized. To do so:
1. Remove the ice hopper lid and lift out the inner
hopper.
2. Loosen the thumbscrew on the agitator
assembly and lift the assembly up and out of the
ice pool.
WARNING: Shaver blade is sharp!
3. Remove the ice chute by pressing the release
button and pulling down on the ice chute.
4. Wipe the inside of the ice pool with a clean soft
cloth dampened with sanitizing solution (see
Cleaning Instructions for recommended
sanitizing solution).
5. Rinse the ice chute, the agitator assembly and
inner hopper in sanitizing solution, and allow to
air dry.
6. Once all parts are dry, slide the agitator
assembly carefully back into place and secure
with the thumbscrew. Align the bosses on inner
hopper with the matching holes in the ice
hopper, making sure that the interlock post is
inserted into the hole behind the inner hopper
fin. Press gently down into place. Reinstall the
ice chute by sliding it back until it clicks into
place (press the button slightly to allow the chute
to slide over the button).
7. Plug the unit into a grounded outlet.
8. Wash and sanitize the blender jar as described
in the section "Cleaning Instructions–Blender".
6/6/12
3:32 PM
Page 5
Leveling
Feet
Drain
Hose
Fitting
Release
Button
Thumbscrew
Shaver
Blade
Jam
Nut
Inner
Hopper
Fin
Alignment
Bosses
Interlock
Post
Agitator
Ice Pool
5