Télécharger Imprimer la page

Maytag Commercial MLE26PRFZW Instructions D'installation page 8

Publicité

LOCATION REQUIREMENTS
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
Your dryer can be installed in a basement, laundry room, or recessed
area.
Dryer as received is not intended for Manufactured/Mobile homes.
An adapter kit per this install instruction is required for this dryer to
be used for a Manufactured/Mobile home.
Companion appliance location requirements should also be
considered.
IMPORTANT: Do not install or store the dryer where it will be
exposed to water and/or the weather. Proper installation is your
responsibility.
You will need:
A grounded electrical outlet located within 6 ft (1.8 m) of
where the power cord is attached to the back of the dryer. See
"Electrical Requirements. "
A level floor with a maximum slope of 1" (25 mm) under entire
dryer. Installing the dryer on soft floor surfaces, such as carpets
or surfaces with foam backing, is not recommended.
Dryer installation clearances
The location must be large enough to allow the dryer door to be
fully opened.
Additional spacing should be considered for ease of installation
and servicing. The door opens more than 180°.
Additional clearances might be required for wall, door, and floor
moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
The back of the dryer shall be installed against a wall. Refer to
the minimum installation dimensions/clearances in the diagrams.
8
When installing a gas dryer:
IMPORTANT: Observe all governing codes and ordinances.
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
Make sure that lower edges of the cabinet, plus the back and
bottom sides of the dryer, are free of obstructions to permit
adequate clearance of air openings for combustion air. See
"Recessed Area Installation Instructions" below for minimum
spacing requirements.
Recessed Area Installation Instructions
This dryer may be installed in a recessed area. For recessed area
installations, minimum clearances can be found on the warning label
on the rear of the dryer or in "Dimensions/Clearances. "
The installation spacing is in inches and is the minimum allowable.
Additional spacing should be considered for ease of installation,
servicing, and compliance with local codes and ordinances.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same closet
as the dryer.

Publicité