rror codes and protection code
E
EH60-Humidity sensor error--Unplug the unit and
plug it back in. If error repeats, call for service;
EH61-Tube Temperature sensor of the evaporator
error-- Unplug the unit and plug it back in. If
error repeats, call for service;
EH02-Zero-crossing signal detection error; If error
repeats, call for service;
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied.
Auto Shut Off
The
dehumidifier
shuts off when the bucket is
full, or when the bucket is removed or not replaced
in the proper position.When the setting humidity is
reached, the unit will be shut off automatically.
For some models,the fan motor will continue
operating.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light(Clean filter indicator light) flashes at one time
per second, after finishing clean the air filter, press
the Filter pad and the Reset light(Clean filter indicator
light) goes off.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
EH03-Indoor fan speed malfunction; If error repeats,
call for service;
EH0b-Indoor PCB and display board communication
error; If error repeats, call for service;
Protection Code:
P2-Bucket is full or bucket is not in right position--
Empty the bucket and replace it in the right
position. On some models, the water full light
illuminates.
Setting the Timer
When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.
31