TURBO Button
Control the Turbo speed. Press to select either
Turbo or normal fan speed. Set the Turbo control
to high for maximum moisture removal. When
room humidity is at your preferred level, it is
advised to turn off Turbo speed.
TIMER Button
Starts the Timer ON and Timer OFF function setting.
Up/Down Buttons (
/
• Humidity Set Control Buttons
The humidity level can be set within a range
of 35% RH (Relative Humidity) to 85% RH
(Relative Humidity) in 5% increments.
For drier air, press the
button and set to a
lower value (%).
For damper air, press the
button and set a
higher value (%).
• TIMER Set Control Buttons
Use the
and
key buttons to set the Timer
ON or Timer OFF from 0 to 24 hours.
POWER Button
Press to turn the dehumidifi er on and off .
Other Features
Bucket Full Light
Lights up when the bucket is ready to be emptied.
Auto Shut Off
The dehumidifi er shuts off when the bucket is full,
or when the bucket is removed or not replaced in
the proper position. When the setting humidity is
reached, the compressor will be shut o
automatically. The fan motor will continue
operating additional 3 minutes.
Page 8
LED Display
Shows the set % humidity level from 35% to 85%
or auto start/stop time (0 ~ 24) while setting,
then shows the actual (+/- 5% accuracy) room
% humidity level in a range of 30% RH (Relative
Humidity) to 90% RH (Relative Humidity).
Error Codes and Protection Code:
AS - Humidity sensor error - Unplug the unit
and plug it back in. If error persists, contact
Customer Service.
)
ES - Tube Temperature sensor of the evaporator
error - Unplug the unit and plug it back in. If
error persists, contact Customer Service.
P2 - Bucket is full or bucket is not in right
position - Empty the bucket and replace it
in the right position. (only available for the
unit with no pump feature.)
E3 - Unit malfunction - Unplug the unit and plug
it back in. If error persists, contact Customer
Service.
Eb - Bucket is removed or not in right position -
Replace the bucket in the right position. (only
available for the unit with pump feature.)
Auto Defrost
When frost builds up on the evaporator coils,
the compressor will cycle off and Auto Defrost
function will run automatically.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restarted
in the fi rst 3 minutes to protect compressor
operation. The unit will restart automatically after
3 minutes.
Auto-Restart
If the unit stops unexpectedly due to a power cut,
it will restart with the previous function setting
automatically when the power resumes.