2.
Charging current 12 V AGM battery
–
2 A/4 A/6 A/8 A. The charging
current is set automatically
depending on the battery's capacity
and/or charge.
3.
Winter mode 12 V standard battery and 12
V AGM battery. Suitable at 5°C or lower.
NOTE:
Never charge a frozen battery – always thaw it
out before charging.
4.
Charging current 6 V standard lead-acid
battery
–
2 A/4 A/6 A/8 A. The charging
current is set automatically
depending on the battery's capacity
and/or charge.
5.
Battery charging indicator
–
Each segment represents 20%. A
flashing surround indicates that the
battery is charged. When the
surround and all five segments are
lit, the battery is fully charged and
the product switches to trickle
charging.
6.
Battery voltage, resolution 0.1 V.
7.
Indication of incorrect polarity.
8.
Indication of defective battery.
9.
Symbol for battery clip.
FIG. 1
HOW TO USE
•
The charger's mains plug is inserted, but
no battery is connected
–
The backlight flashes green, 0.0 V is
displayed and the battery clip symbol
is lit.
•
The battery is connected but the charger's
mains plug is not inserted
–
The display is blank.
•
The charger's mains plug is inserted and
the battery is connected
–
The backlight flashes green and the
battery's voltage is displayed. After 5
seconds, the backlight changes to
red and charging begins.
•
Disconnection of clips during charging or
after completed charging
–
The backlight flashes, 0.0 V is
displayed and the battery clip symbol
lights.
•
The charger's mains plug is inserted and
the battery is connected with incorrect
polarity
–
The backlight flashes and the
incorrect polarity symbol is lit.
•
The charger's mains plug is inserted, the
battery is connected and there is voltage
between the clips, although there is little
or no charging current flowing.
–
The clips are not connected correctly
to the battery, for example due to
oxide on the battery terminals. The
display flashes, the battery clips
symbol is lit and the voltage between
the clips is displayed.
MAINTENANCE
•
The product must be stored and used in a
dry, well ventilated area, protected from
heat and direct sunlight as well as from
corrosive gas. When charging, the product
must be placed on a stable surface, as far
from the battery being charged as the
cables permit.
•
Operating temperature: -10 to 40°C
•
Storage temperature: -10 to 50°C
•
Never place the charger on the battery, or
the battery on the charger.
•
Stop the charging if the battery
temperature exceeds 45°C and allow the
battery to cool to the permitted charging
temperature before resuming charging.
EN