Télécharger Imprimer la page

KineticoPRO CC 206s Guide D'utilisation page 9

Publicité

Compact Commercial Softener Owner's Manual
o
S
peratInG
pecIfIcatIonS
System Operation
KineticoPRO Water Softeners use a twin tank design to assure that treated water is always
available. When one tank regenerates, the other supplies treated water. The Kinetico Valve
controls when each tank is in service, when each tank must be regenerated and the regeneration
of each tank.
Level 1 Operation
Regeneration
Level 1 assembly consists of three chambers: inlet, outlet and regeneration chambers.
Inlet
Hard water enters the inlet chamber and travels to the media tank where it is treated. Treated
water moves from the media tank to the outlet chamber. Contained in the outlet chamber is a
water meter turbine, which turns only when water is used. Gears connect the water meter turbine
to the water meter disc. The system's meter gearing is defined as the volume of processed water
needed to turn the water meter disc 360˚.
Outlet
Flow Nozzle
Accuracy and range of the flow meter will depend on the nozzle used with the system. Most units incorporate the half louver
nozzle. This nozzle gives a highly accurate and wide range of flow metering capability. If an alternative nozzle is used, a
different meter volume per 360˚ on the water meter will result. The Half Louver Nozzle is standard with all CC Systems.
Part Number
Min. Flow Range
Max. Flow Range
Meter Gearing
Depending on the gear stack used, the volume of water per 360˚ on the water meter will change. Some of the gear
stacks used are listed.
Gearing
(0.05-0.15 gpm)
2-2-2-3
2-2-1-5
2-2-7-6*
2-2-3-4
2-1-5-4**
2-7-6-4
2-3-4-4
1-5-4-4
7-23-23-6
7-6-4-4
3-4-4-4
* Standard CC 206 Models
** Standard CC 208 Models
Micro
10880B
0.05 gpm
5.00 gpm
Micro
Micro
(0.15-0.50 gpm)
36
146
40
163
61
250
69
282
77
315
119
484
134
546
149
609
180
735
230
936
289
1,056
Half Louver
Full Louver
11018
0.3 gpm
25.00 gpm
40.00 gpm
Half Louver
342
381
600*
657
750**
1,119
1,253
1,408
1,715
2,168
2,431
8
Open Louver
11019
0.75 gpm
1.10 gpm
50.00 gpm
Full Louver
Open Louver
760
848
1,303
1,470
1,639
2,520
2,843
3,171
3,829
4,873
5,498
15653
1,291
1,440
2,213
2,497
2,785
4,280
4,829
5,386
6,504
8,279
9,340