Télécharger Imprimer la page

KineticoPRO CC 206s Guide D'utilisation page 17

Publicité

Compact Commercial Softener Owner's Manual
Adjuster Tube Setting
The Adjuster Tube is set by cutting and removing tabs on both sides of the tube. Using a pocket-knife,
cut across each tab horizontally, following the channel in the plastic. Break off each tab individually
until the proper setting is reached. The remaining number or letter imprinted on the tab determines
the correct setting. *Note: With Cabinet models, there is no adjuster tube setting.
Float Cup Setting
The float cup is set by adjusting its height above the bottom of the brine valve assembly. By
removing the brine valve assembly and resting it on a flat surface, the height of the float cup can
be measured with a ruler. The height is measured from the base of the brine valve assembly to the
top of the float cup. (See drawing at right.) Note that standard settings are defined by markings
on the rod of the brine valve assembly. The settings on the rod are listed in the tables at the end of
this section. Where the predefined settings are not adequate, the actual float cup height, in inches,
is listed, and the setting must be measured and set according to the measured float cup height.
Installing the Brine Valve
After the adjustments have been made to the adjuster tube and the float cup, the brine valve
assembly must be installed in the brine drum. Locate the brine valve in the brine well so that the
3/8" bent tube is along the back of the brine well away from the brine drum wall. The 3/8" bent
tube snaps into a notch and extends from the brine drum about 1".
Do not drop the brine valve into the drum! Dropping may lower the float cup, resulting in an
improper setting.
Brine Valve Settings
Unit
Brine Setting
CC 206
0.5 lb Setting
CC 206
1.0 lb Setting
CC 208
1.0 lb Setting
CC 208
1.4 lb Setting
9.
Add a clean grade of salt at this time. DO NOT USE ROCK SALT.
On iron-bearing water, a salt that contains resin cleaning additives is recommended.
10. Open the inlet valve and allow tanks to fill slowly with water. Water will run at the drain until unit is full and pressurized.
11. With the unit in service and under pressure, allow the brine drum to fill with water until the brine valve shuts off.
12. After the unit is fully pressurized, purge air from the lines by opening soft water outlet.
When installation is complete, plumbing lines must be chlorinated for sanitation. Common household bleach
may be used. The amount of bleach will vary on plumbing size, length and fixtures.
13. VERY IMPORTANT! Where a brine drum overflow could cause damage, a 1/2" I.D. overflow line must be installed on
the overflow fitting on drum and connected to a drain. Make sure overflow line is not higher than the overflow fitting.
FOLLOW STATE AND LOCAL CODES.
14. Before leaving installation, check plumbing for leaks.
206 Cabinet
208 Cabinet
() 5 ¼"
() 6 ¼"
X
() 5¼"
X
() 5¾"
16
12x20"
X
(1) 7"
X
(1.5) 7¼"
(1.5) 7¼"
(A) 7½"
(adjuster tube) Float Cup Height (to top of float)
Note: cabinet models have no adjuster tube setting
Adjuster Tube
Float
Cup
Height
18 x 35"
X
(1) 7¾"
(1) 7¾"
(1.5) 7¾"

Publicité

loading

Ce manuel est également adapté pour:

Cc 206cCc 208sCc 208cCc 208h