CONTROL UNIT
4.2

Inputs and outputs

START (using button with N.O. contact or remote control)
- starts the automation (opening or closing) on the basis of
the current state and the operating logic settings.
STOP (button with N.C. contact) - the input stops the
wing immediately. A START pulse is required to continue
movement. The STOP input has priority over all other
functions at all times.
Closing photocells - these photocells are only enabled on
the closing stroke. When triggered they will stop the movement
for 1 sec. and then start to reopen the gate. These photocells
will prevent closing as long as they are covered.
Auxiliary safety edge operating on opening stroke -
this is a safety input enabled during the opening stroke. The
safety edge will trigger if it touches an obstacle during the
opening stroke. The wing will reverse for a short distance
and then stop. You must press START, the gate will close.
Auxiliary opening safety photocells - these photocells
detect obstacles on the opening and closing strokes; they
will trigger on detecting an obstruction and stop the gate.
The movement will only restart when the photocells are
uncovered. After 1 sec. of pause, the movement will restart
in the original direction.
To signal the status of the automation:
Warning light (remote signal):
AUTOMATION STATUS
FLASHING LIGHT
gate opening
fl ashing (1 sec.)
gate closing
fl ashing (1 sec.)
gate open
light OFF (parameter
gate closed/stopped light OFF
auxiliary safety
light ON
routine maintenance fl ashing (0.5 sec.)
• Auxiliary output using external relay depending on
ae
(
) parameter: 2 sec pulse type with activation by remote
ch1
4
control (
-
) (ex: pedestrian gate electric lock actuation)
OR timer (ex: lighting).
Courtesy light - light ON when START or PEDESTRIAN
START is pressed, with programmable timer (
4.3

Checks and warnings on display

To switch ON the display, press the
To switch OFF the display, press once quickly again.
5.

PROGRAMMING THE PARAMETERS

IMPORTANT! The gate must be stopped and closed before you can start programming.
WARNING: All input signals will be ignored during programming.
Press and hold RED button
Release the RED button
BLUE
RED when a parameter shown
pressing the BLUE button
Press and hold the RED button for 3 seconds
The parameter has now been modifi ed. More modifi cations can be made before you exit the programming function.
WARNING: modifi cations are only confi rmed when you exit the programming function (display switched OFF).
If the power supply fails for any reason during programming, all the modifi cations you have made will be lost.
To EXIT programming:
Parameters enabling RESET or operations involving MEMORIES: before the modifi cation is confi rmed the display shows
if confi rmation is given (RED button)
Flashing light /
WARNING LIGHT
light ON
fl ashing
AH
) light ON
light OFF
-
-
ae
).
YELLOW once quickly.
to select a new value
Release the RED button
YELLOW
donE
fl ashes for 3 sec.
SLIDE 230 APRICODE
fi g. 6 -
Checks and warnings on display
1
2
8 8 8 8
display 1: GATE STATUS
C
= CLOSED
b
= OPENING
A
= OPEN
d
= CLOSING
E
= LOCKED
0
= OBSTACLE detection
8
display 2: INPUTS (ON=contact closed)
2
1 = START radio
2 = CLOSING PHOTOCELL
4 = PEDESTRIAN START
7
5 = SAFETY DEVICE during OPENING
6
4
6 = START
5
7 = STOP
8
display 3: LIMIT SWITCHES
1
(OFF=the limit switch is triggered)
1 = OPENING limit switch
6
6 = CLOSING limit switch
8
display 4: OUTPUTS
1
3
(ON=output active)
1 = FLASHING LIGHT
3 = WARNING LIGHT
ERROR CODES
noEE
= failed access to memory during the power up;
Init
= missing of data in memory (press YELLOW and
BLUE simultaneously for approx. 3 sec.
display press START);
Er1
= failed access to the memory during UPLOAD/DOWNLOAD;
Er2
= closing photocell test;
Er3
= auxiliary photocell test;
Er9
= motor/limit switches (verify the connection)
ErFc
= STOP due to a failure of the limit switches
MAn
(fl ashes for approximately 3 sec. when programming
is accessed) = routine maintenance is required.
PROC
the display shows
displays the fi rst parameter with the value set
scrolls through the parameters
shows the value set (marked by the bullet)
scrolls through the values
3 fl ashes confi rm the modifi cation
the new setting is displayed
returns to the parameters
press the YELLOW button until the display is switched OFF
Er
(positive outcome) o
+ error code in the event of failure.