QUERY MODE
Press "
" button to turn on the AC, then hold the remote controller's buttons "
"
" for 5 seconds to enter the Query mode. The LCD window will display 00. Press "
or "
" button to select code 00~99, then press MODE to transmit the signal.
Codes
Indoor Display Indication
Cancel the following 01-07 display, Display
00
setting temperature
01
Display the indoor enverinment temperature
02
Display the indoor pipe temperature
03
Display the outdoor enverinment temperature
04
Display the outdoor pipe temperature
05
Display the discharge temperature
06
Display the current(amp)
07
Display the protection code, if there is error display "--"
08
Reserved
09
Reserved
Cancel the following 11-18 display,
10
Display setting temperature
Display the compressor frequency
11
12
Display the left indoor fan motor speed
13
Display the outdoor fan motor speed
14
Display the current(amp) of compressor
15
Display the EEV data
16
Display the AC power voltage
Display the DC power voltage
17
18
Display the right indoor fan motor speed
19~78
Reserved
79
Auto-start
If the data on the indoor display
•
is shining means minus "-" or
thounds data; eg. "25" and
shining means 25ºC.
"A" means 10, B means 11, C
•
means 12, D means 13, E means
14, F means 15;
• Temperature: -40~159℃; eg.C8
and no shining means 128ºC;
Frequency: 0~159Hz: eg. B0
•
means 110Hz;
Fan speed: 0~2000 rpm, display
•
data= actual data/10, round to
tens place; eg. "38" and shining,
means 1375~1384 rpm, "77" and
no shining, means 765~774 rpm
EEV datas: 0~999 display data=
actual data/10, round to tens
place; eg. "28" means 275~284.
• Current datas: round to ones
place; eg. "9" means 8.5A~9.4A;
• Voltage datas: display data=
actual data/10,
/
ON or OF
6
"and
"
Rules
V.1