Télécharger Imprimer la page

LG LSDG389VS Mode D'emploi page 32

Masquer les pouces Voir aussi pour LSDG389VS:

Publicité

THE LCD DISPLAY
FLOW SENSE™ DUCT BLOCkAGE
H
SENSING SYSTEM INDICATOR
The FLOW SENSE™ duct blockage sensing
system detects and alerts you to blockages
in the ductwork that reduce exhaust flow
from the dryer. This improves operating
efficiency and helps minimize service calls,
saving you money.
If no bars are shown in the
display, the ductwork is free from
blockages.
If two bars in the display are
lighted, examine the dryer
exhaust system for lint build up
or other restrictions, including
damage, excess length, foreign
objects, etc. See note below.
If all bars are lit, the dryer
ductwork has a blockage
that needs to be removed
immediately.
NOTE: If the duct has been checked and
cleaned and two bars are still displayed after
several cycles, then there is some restriction
in the duct due to length, condition, etc. In
this case, no further action is necessary and
the dryer can be used normally. However,
drying times may be increased and there may
be some reduction in operating efficiency
32
(cont.)
• 2 bars are displayed In the LCD screen.
1. Possible causes
• Ductwork is slightly too long or has too
many turns/restrictions.
• Partial blockage of the ductwork due to lint
buildup.
2. Solutions
• I nstall a shorter or straighter duct run. See
the Installation Instructions.
• D uctwork should be checked/cleaned soon.
Dryer can be used in this condition, but
drying times may be longer.
• If END OF CYCLE is displayed after the end
of cycle, it will be off in 4 minutes. If POWER
button is pressed or the door is opened,
power will be off immediately.
• 4 bars are displayed In the LCD screen.
1. Possible causes
• Ductwork is too long or has too many turns/
restrictions.
• Significant blockage of the ductwork due to
lint buildup or debris.
2. Solutions
• Install a shorter or straighter duct run. See
the Installation Instructions.
• D uctwork should be checked/cleaned soon.
Dryer can be used in this condition, but
drying times may be longer.
• I f NEED FLOW CHECK is displayed after
the end of cycle, it will be off in 2 hours. If
POWER button is pressed or the door is
opened, power will be off immediately.
END OF CYCLE
NEED FLOW CHECK
THE DUCTWORK HAS
A BLOCKAGE THAT NEEDS
TO BE REMOVED
IMMEDIATELY.

Publicité

loading

Ce manuel est également adapté pour:

Lsde388vsLsdg389vs.asseeusLsde388vs.asseeus