9. REPLACING THE SPINDLE
For augers having a Ø 16 mm shank, the "MND1" spindle must be interchanged with the stand-
ard "MND" spindle.
Replace the spindle as follows:
9.1) Removing the "MND" spindle
– Remove the detachable guard PRM-UN and the auger (see § 4.1.1).
– Turn the fixed guard (23) and remove from the spindle, exposing the spindle shaft (15).
– By means of the 4 mm allen key supplied with the machine, remove grubscrew (18).
– Remove circlip (16) and locating pin (17).
– Slide the spindle from the shaft (13).
9.2) Fitting the "MND1" spindle
– Slide the "MND 1" spindle onto the shaft (15). Ensure that the spindle guide (19) is correclty po-
sitioned.
– Align the hole on the shaft (13) with the corresponding holes on the spindle (20).
– Insert the locating pin (17) and fit the circlip (16).
– Fit and tighten the grubscrew (18).
– Fit the fixed guard (23).
– Insert and secure the auger (Ø 16 mm shank); (see § 9.3).
– Fit the detachable guard PRM-UN (see § 4.1.2).
9.3) Fitting and removing the auger on the "MND1" spindle
– Turn the emergency lever (12), align the two
grooves on the auger with the red reference line
on the end of the spindle and fully insert the auger.
– Release the emergency lever (12).
To remove the auger, turn the emergency lever
(12) extract the auger from the spindle.
10. RETURN TO CEMBRE FOR OVERHAUL
For all maintenance or repair requests, please fill out the form available at www.cembre.com
on the product page or at the following link: https://my.cembre.com/login (subject to prior
registration)..
For any other needs, please contact your local distributor or Sales Engineer who will advise you
and provide the necessary instructions for returning the product to our warehouse.
13
(See Fig. 1 and 2)
Grooves on the
auger
Red reference line
on the spindle
ENGLISH