FORMULA SELECT - INSTRUCTIONS
The BrightLogic laundry Formula Select module (optional) allows remote selection of up to 20
different wash programs, program names can be displayed by uploading via the computer program.
The Formula Select module can also be used to prime and stop the pumps.
The desired program must be selected, using the UP and DOWN keys on the module and
pressing enter, before beginning the wash cycle.
Resetting options
There are four options available to reset the formula select:
Reset Formula to Program 01 - (default setting)
Reset Formula to Program 00 - (blank program)
Reset Formula to Program 02 - (set to any program number)
Reset Formula to Previous program - (resets to the previous program)
The unit can be manually reset by pressing the up and down keys together for 1 second.
Without a Formula Select module
If there is no formula select installed then the programs can still be selected from the unit itself.
From the default screen press the PROGRAM button to toggle the correct program.
FORMULA SELECT - INSTALLATION
Fit the module to a suitable surface, in an accessible area, using the self-adhesive Velcro provided.
Before fitting, please ensure that the power to the unit has been isolated.
Open the lid of the main enclosure.
Pass the cable through the gland situated on the bottom of the unit and run it to the vicinity of the
Formula Select connection socket on the board (bottom right).
Note:
Screened cable should be used.
Fit the green connector with the coloured wire in the order shown above. Plug the connector into the
correct socket and tighten the gland to grip the cable.
REMOVE links LK3 & LK4
Revision 1.1
09/2024
B1051UL
RED
COMMON
COMMON
BLACK
ISOLATED
B RAIL
B
YELLOW
RAIL
WHITE
GREEN
BLUE
N
L
A
RAIL
COMMON
B RAIL
FORMULA SELECT - INSTRUCTIONS