Télécharger Imprimer la page

Tempco FIX ECO 3 Manuel D'installation Et D'utilisation page 11

Publicité

5. SAFETY THERMOSTAT
1. DESCRIZIONE DEI COMPONENTI
5. SICHERHEITSTEMPERATURWÄCHTER
5.1 Adjustable thermostat
With external capillary
Boxed unipolar thermostat, liquid expansion, with switching
contacts, complete with core hitch. The operating temperature of the
thermostat is (Factory setting 55°C) and adjustable by screwdriver. The
thermostat is for the mechanical saftey temperature shut off concerning
EN 1264.
Text not necessary, because it is pre-mounted. Replace text with:
For changing the presetting of the thermostat, please remove the black
cap on the front side of the thermostat and change the temperature with
a small screw driver.
Terminal 1 = common.
Terminal 2 = opens the circuit when the set
temperature is reached.
Terminal 3 = not used, closed if temperture
override
5.1 Sicherheitstemperaturwächter
Mit externem Kapillarohr
Einpoliger Sicherheitstemperaturwächter mit externem Kapillarrohrfühler
und Wechslerkontakt. Die Temperatur des Sicherheitstemperaturwächters
ist voreingestellt (Werkseinstellung 55°C) und durch einen Schraubenzieher
regu¬lierbar. Er dient der mechanischen Sicherheitstemperaturabschaltung
gemäß EN 1264.
ANSCHLÜSSE
Um
die
werkseitig
Sicherheitstemperaturwächters zu ändern, entfernen Sie bitte die schwar-
ze Kappe an der Vorderseite. Danach können sie die Temperatur mit einem
kleinen Schraubenzieher verstellen.
Klemme 1 = Phase L
+
°C
T
Klemme 2 = Öffnerkontakt (Öffnet wenn voreingestellte
Klemme 3 = Schließerkontakt (Nicht belegt!!
2
3 1
U
PH
N
voreingestellte
Temperatur
Temperatur überschritten)
Schließt wenn voreingestellte
Temperatur überschritten
EN
EN
DE
DE
des
11