UHF SPECTRE Access module
Installation procedure
TM
Read-only & OSDP
modules
Only STid antennas can be used with read-only and OSDPTM modules. Please refer to the STid antenna installation procedure for module/antenna compatibility.
The number of antennas & channels and the communication protocol are configurable with the Ultrys V2 application or when the module is ordered. Please
refer to Ultrys for more details about configuration settings.
•
TTL protocols (Wiegand & ISO2): please refer to Spec_Protocole_Wiegand_V2.1_EN & Spec_Protocole_Clock&Data_V2.1_EN.
•
Serial protocols (RS232 & RS485): the structure of the frame can be configured with the ULTRYS application with the following optional parameters (in
gray):
ASCII: if this option is activated, the data will be sent in ASCII mode (data size will be doubled)
-
Padding: complete the tag data with not significant 0 to obtain the defined data size - (Channel no. + 0 padding + tag data).
-
•
OSDP™ protocol (RS485: 7OS): please refer to ULTRYS for more details about configuration settings + refer to Spec_Protocole_7OS_OSDP_UHF-EN.pdf.
When the module is switched on, the module's red LED lights up. Module initializing.
After initializing, the module will look for a configuration tag for about 15 s, on antenna 1 (connected to RF port 1).
• If no tag detected: the antenna LED flashes "color RFON" (200ms) (blue by default) / RFOFF (200ms).
• If any tag detected: the antenna LED displays the sequence "color RFON" (blue by default) / "color DETECTION" (orange by default) for 200ms then LED OFF.
• If a configuration tag is detected: the antenna LED displays the sequence « color RFON "(blue by default) / "color DETECTION" (orange by default) for 200ms
then LED OFF, then the antenna LED gives the followings indications:
3 GREEN flashes (500ms ON; 200ms OFF): the configuration tag is taken into account.
-
3 RED flashes (500ms ON; 200ms OFF): the regulation (region) of the configuration tag does not match to the regulation of the reader.
-
3 PURPLE flashes (500ms ON; 200ms OFF): the key of the configuration tag does match to the reader key.
-
5 RED flashes (500ms ON; 200ms OFF): the model of the reader of the configuration tag does match to the model of the reader.
-
The end of the start sequence is indicated by the flashing of the reader LEDs (red and green) 3 times (500ms ON; 500ms OFF).
Power supply OK:
fixed red LED
Power supply too low:
blinking red LED (500ms ON / 500ms OFF)
Temperature error:
blinking red LED 5 times after all reading sequence. (RF Scan)
RF error, antenna problem:
blinking red LED 3 times after all reading sequence. (RF Scan)
Communication:
green LED
SSCP
®
modules
When the module is switched on, the module's red LED lights up. Reader initializing.
After initializing:
•
If the module is a RS232 module: module's green LED blinked 3 times.
•
If the module is a RS485 module: module's red LED blinked 3 times.
The module then waits for command.
More details about reader's communication are available in the protocol specification: Spec_Protocole_SSCP_UHF_ACCESS.
Power supply OK:
fixed red LED
Power supply too low:
blinking red LED (500ms ON / 500ms OFF)
Communication:
Green LED
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1127X08 - Page 3 sur 15 - Ed. 28/10/2024
STid reserves the right to make change without notice, for the purpose of product improvement.
Module UHF SPECTRE Access
Notice d'installation
1 byte
1 byte + X bytes
STX
Channel number + Tag Data*
0x02
0x0y nn.....nn
Módulo UHF SPECTRE Access
Manual de instalación
Configuration
1 byte
1 byte
LRC
CR
0x0D
Start Sequence
Red/Green Module LED indication
Operating Mode
Red/Green Module LED indication
1 byte
1 byte
LF
ETX
0x0A
0x03
US
FR