Télécharger Imprimer la page

Stid SPECTRE Notice D'installation page 2

Masquer les pouces Voir aussi pour SPECTRE:

Publicité

UHF SPECTRE Access module
Installation procedure
Frequency Band
ETSI & India
SMA-R41-A/U04-xx: TTL
865 - 868 MHz
SMA-R42-A/U04-5AB: RS232
SMA-R43-A/U04-7AB: RS485
SMA-W43-A/U04-7OS: OSDP™ v1 & v2 - RS485
SMA-W42-A/U04-5AX: SSCP
SMA-W43-A/U04-7AX: SSCP
FCC & ISED PMN
SMA-R51-A/U04-xx: TTL
902 - 928 MHz
SMA-R52-A/U04-5AB: RS232
SMA-R53-A/U04-7AB: RS485
SMA-W53-A/U04-7OS: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX: SSCP
SMA-W53-A/U04-7AX: SSCP
Peru
SMA-R51-A/U04-xx1PE: TTL
916 - 928 MHz
SMA-R52-A/U04-5AB1PE: RS232
SMA-R53-A/U04-7AB1PE: RS485
SMA-W53-A/U04-7OS1PE: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX1PE: SSCP
SMA-W53-A/U04-7AX1PE: SSCP
New-Zealand
SMA-R51-A/U04-xx1NZ: TTL
922 - 928 MHz
SMA-R52-A/U04-5AB1NZ: RS232
SMA-R53-A/U04-7AB1NZ: RS485
SMA-W53-A/U04-7OS1NZ: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX1NZ: SSCP
SMA-W53-A/U04-7AX1NZ: SSCP
Use an AC/DC power supply LPS type, Limited Power Source (as per IEC EN 60950-1 Ed2) or ES1 type, PS1 (as per IEC EN 62368-1) for main supply and for an
eventual V+/V-.
Main power supply:
Range +9 Vdc up to +36 Vdc
Advice:
To overcome the cable length effect on the supply voltage seen by the reader, it is recommended to use a 24V power supply
Consumption:
Typical: 1A under +12 Vdc
RS485 (L+ & L-) / RS232 (Tx)
Communication:
TTL (Wiegand / Clock & Data)
Pin out:
Temperature:
Protection:
Chip:
I/O:
Module LED:
RS485:
Use a multi-conductor shielded twisted
RS232:
pair cable - Max length 49.21 ft / 15 m.
Use a multi-conductor shielded untwisted
2 cable AWG24 – 30 m / 98.4 ft max
4 cables AWG24 – 60 m / 196.9 ft max
Wiegand /
Clock & Data:
6 cables AWG24 – 100 m / 328.1 ft max
2 cable AWG20 – 50 m / 164. ft max
4 cables AWG20 – 100 m / 328.1 ft max
Install the module away from computer transmission cables or from power sources (ex: RJ45, AC power line...).
The disruptions that they can cause can vary according to their radiation power and their proximity.
Use a filtered and regulated power supply.
Antennas connected to different modules may interfere with each other. Move them away from each other.
A power supply which provides 1.5 A min under +12Vdc is recommended.
If the IN/OUT are powered by the module, use a 2A min under +12Vdc power supply.
Users must not remain within a range of less than, 34 cm / 13.39 in from an antenna for an extended period of time as per EN50364 applicable to this
type of device.
Only the hatch can be opened.
Before any service operation you must de-energize reader.
Check that the hatch seal is correctly positioned before closing.
Do not remove the caps of unused
cable glands:
Careful: There is a 5.5 volts DC on each RF port.
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1127X08 - Page 1 sur 15 - Ed. 28/10/2024
STid reserves the right to make change without notice, for the purpose of product improvement.
Module UHF SPECTRE Access
Notice d'installation
References
®
v1 & v2 - RS232
®
v1 & v2 - RS485
v1 & v2 - RS232
®
®
v1 & v2 - RS485
®
v1 & v2 - RS232
v1 & v2 - RS485
®
v1 & v2 - RS232
®
v1 & v2 - RS485
®
Power Supply Characteristics
Typical: 12 Vdc
Max: 1.5A under +12 Vdc
Read-only
Terminal block plug 3x4 pins and 1x8 pins, thread 3.81 mm / 0.149 in
1 red LED: presence of power supply and 1 green LED: activity on Reader / host link
Recommended Cables
Read-only
Use a multi-conductor shielded twisted pair cable - Max length 3 280 ft / 1000 m at 9600 baud.
Recommendations
Do not remove the caps from the
unused RF connectors:
Módulo UHF SPECTRE Access
Manual de instalación
Frequency Band
Morocco
865.7 MHz
Philippines
918 - 920 MHz
Australia
920 - 926 MHz
Characteristics
OSDP
TM
RS485 (L+ & L-)
-25 to +60 °C / -13 to +140 °F
IK10 certified Reader casing - IP66
EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max
4 optocoupled inputs and 4 optocoupled outputs
OSDP
TM
--
--
References
SMA-R41-A/U04-xx1M: TTL
SMA-R42-A/U04-5AB1M: RS232
SMA-R43-A/U04-7AB1M: RS485
SMA-W43-A/U04-7OS1M: OSDP™ v1 & v2 - RS485
SMA-W42-A/U04-5AX1M: SSCP
SMA-W43-A/U04-7AX1M: SSCP
SMA-R51-A/U04-xx1PH: TTL
SMA-R52-A/U04-5AB1PH: RS232
SMA-R53-A/U04-7AB1PH: RS485
SMA-W53-A/U04-7OS1PH: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX1PH: SSCP
SMA-W53-A/U04-7AX1PH: SSCP
SMA-R51-A/U04-xx1AU: TTL
SMA-R52-A/U04-5AB1AU: RS232
SMA-R53-A/U04-7AB1AU: RS485
SMA-W53-A/U04-7OS1AU: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX1AU: SSCP
SMA-W53-A/U04-7AX1AU: SSCP
SSCP
®
RS485 (L+ & L-) / RS232 (Tx & Rx)
SSCP
®
Use a multi-conductor shielded twisted
pair cable - Max length 49.21 ft / 15 m.
--
Install the reader with the word UP
facing
upwards
in
that
connectors are down:
US
FR
ES
®
v1 & v2 - RS232
®
v1 & v2 - RS485
v1 & v2 - RS232
®
®
v1 & v2 - RS485
®
v1 & v2 - RS232
v1 & v2 - RS485
®
way
the

Publicité

loading