UHF SPECTRE Access module
Installation procedure
Frequency Band
ETSI & India
SMA-R41-A/U04-xx: TTL
865 - 868 MHz
SMA-R42-A/U04-5AB: RS232
SMA-R43-A/U04-7AB: RS485
SMA-W43-A/U04-7OS: OSDP™ v1 & v2 - RS485
SMA-W42-A/U04-5AX: SSCP
SMA-W43-A/U04-7AX: SSCP
FCC & ISED PMN
SMA-R51-A/U04-xx: TTL
902 - 928 MHz
SMA-R52-A/U04-5AB: RS232
SMA-R53-A/U04-7AB: RS485
SMA-W53-A/U04-7OS: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX: SSCP
SMA-W53-A/U04-7AX: SSCP
Peru
SMA-R51-A/U04-xx1PE: TTL
916 - 928 MHz
SMA-R52-A/U04-5AB1PE: RS232
SMA-R53-A/U04-7AB1PE: RS485
SMA-W53-A/U04-7OS1PE: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX1PE: SSCP
SMA-W53-A/U04-7AX1PE: SSCP
New-Zealand
SMA-R51-A/U04-xx1NZ: TTL
922 - 928 MHz
SMA-R52-A/U04-5AB1NZ: RS232
SMA-R53-A/U04-7AB1NZ: RS485
SMA-W53-A/U04-7OS1NZ: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX1NZ: SSCP
SMA-W53-A/U04-7AX1NZ: SSCP
Use an AC/DC power supply LPS type, Limited Power Source (as per IEC EN 60950-1 Ed2) or ES1 type, PS1 (as per IEC EN 62368-1) for main supply and for an
eventual V+/V-.
Main power supply:
Range +9 Vdc up to +36 Vdc
Advice:
To overcome the cable length effect on the supply voltage seen by the reader, it is recommended to use a 24V power supply
Consumption:
Typical: 1A under +12 Vdc
RS485 (L+ & L-) / RS232 (Tx)
Communication:
TTL (Wiegand / Clock & Data)
Pin out:
Temperature:
Protection:
Chip:
I/O:
Module LED:
RS485:
Use a multi-conductor shielded twisted
RS232:
pair cable - Max length 49.21 ft / 15 m.
Use a multi-conductor shielded untwisted
2 cable AWG24 – 30 m / 98.4 ft max
4 cables AWG24 – 60 m / 196.9 ft max
Wiegand /
Clock & Data:
6 cables AWG24 – 100 m / 328.1 ft max
2 cable AWG20 – 50 m / 164. ft max
4 cables AWG20 – 100 m / 328.1 ft max
•
Install the module away from computer transmission cables or from power sources (ex: RJ45, AC power line...).
•
The disruptions that they can cause can vary according to their radiation power and their proximity.
•
Use a filtered and regulated power supply.
•
Antennas connected to different modules may interfere with each other. Move them away from each other.
•
A power supply which provides 1.5 A min under +12Vdc is recommended.
•
If the IN/OUT are powered by the module, use a 2A min under +12Vdc power supply.
•
Users must not remain within a range of less than, 34 cm / 13.39 in from an antenna for an extended period of time as per EN50364 applicable to this
type of device.
•
Only the hatch can be opened.
•
Before any service operation you must de-energize reader.
•
Check that the hatch seal is correctly positioned before closing.
•
Do not remove the caps of unused
cable glands:
•
Careful: There is a 5.5 volts DC on each RF port.
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1127X08 - Page 1 sur 15 - Ed. 28/10/2024
STid reserves the right to make change without notice, for the purpose of product improvement.
Module UHF SPECTRE Access
Notice d'installation
References
®
v1 & v2 - RS232
®
v1 & v2 - RS485
v1 & v2 - RS232
®
®
v1 & v2 - RS485
®
v1 & v2 - RS232
v1 & v2 - RS485
®
v1 & v2 - RS232
®
v1 & v2 - RS485
®
Power Supply Characteristics
Typical: 12 Vdc
Max: 1.5A under +12 Vdc
Read-only
Terminal block plug 3x4 pins and 1x8 pins, thread 3.81 mm / 0.149 in
1 red LED: presence of power supply and 1 green LED: activity on Reader / host link
Recommended Cables
Read-only
Use a multi-conductor shielded twisted pair cable - Max length 3 280 ft / 1000 m at 9600 baud.
Recommendations
•
Do not remove the caps from the
unused RF connectors:
Módulo UHF SPECTRE Access
Manual de instalación
Frequency Band
Morocco
865.7 MHz
Philippines
918 - 920 MHz
Australia
920 - 926 MHz
Characteristics
OSDP
TM
RS485 (L+ & L-)
-25 to +60 °C / -13 to +140 °F
IK10 certified Reader casing - IP66
EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max
4 optocoupled inputs and 4 optocoupled outputs
OSDP
TM
--
--
References
SMA-R41-A/U04-xx1M: TTL
SMA-R42-A/U04-5AB1M: RS232
SMA-R43-A/U04-7AB1M: RS485
SMA-W43-A/U04-7OS1M: OSDP™ v1 & v2 - RS485
SMA-W42-A/U04-5AX1M: SSCP
SMA-W43-A/U04-7AX1M: SSCP
SMA-R51-A/U04-xx1PH: TTL
SMA-R52-A/U04-5AB1PH: RS232
SMA-R53-A/U04-7AB1PH: RS485
SMA-W53-A/U04-7OS1PH: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX1PH: SSCP
SMA-W53-A/U04-7AX1PH: SSCP
SMA-R51-A/U04-xx1AU: TTL
SMA-R52-A/U04-5AB1AU: RS232
SMA-R53-A/U04-7AB1AU: RS485
SMA-W53-A/U04-7OS1AU: OSDP™ v1 & v2 - RS485
SMA-W52-A/U04-5AX1AU: SSCP
SMA-W53-A/U04-7AX1AU: SSCP
SSCP
®
RS485 (L+ & L-) / RS232 (Tx & Rx)
SSCP
®
Use a multi-conductor shielded twisted
pair cable - Max length 49.21 ft / 15 m.
--
•
Install the reader with the word UP
facing
upwards
in
that
connectors are down:
US
FR
ES
®
v1 & v2 - RS232
®
v1 & v2 - RS485
v1 & v2 - RS232
®
®
v1 & v2 - RS485
®
v1 & v2 - RS232
v1 & v2 - RS485
®
way
the