Télécharger Imprimer la page

Beurer BF 405 Signature Line Mode D'emploi page 12

Masquer les pouces Voir aussi pour BF 405 Signature Line:

Publicité

Switch on the scale and press the UNIT button
the device.
6. CLEANING AND MAINTENANCE
Clean the surface of the scale from time to time using a slightly damp
cloth. Do not use the scale again until the surface is completely dry.
• Do not use any abrasive cleaning products.
• Never submerge the scale in water. Never rinse the
scale under running water.
• Do not place any objects on the scale when it is not
in use.
• Protect the scale from knocks, moisture, dust, che-
micals, drastic changes in temperature and nearby
sources of heat (ovens, heaters).
7. WHAT IF THERE ARE PROBLEMS?
7.1 Resetting the scale to factory settings
To reset the scale to its factory settings, switch on the scale and
press and hold the UNIT button
seconds until "CLr" is displayed.
7.2 Messages and errors
Display
Cause / Remedy
Discrep-
Incorrect zero point. Briefly press on the scale until
ancy in
the current weight is displayed, then remove your
weight
foot so that "0.0" flashes.
needs to be paired: start/allow pairing/
®
Bluetooth
bonding on your smartphone (note any messages
PAir
in the status bar/notification bar), and confirm the
6-digit pairing code using the SET button
device and confirm on the smartphone.
Connect the scale using the app. Do not connect it
"USE APP"
via the Bluetooth
connect it via the app.
The scale was unable to assign the measurement to
a scale user. If the automatic scale user detection
function is not working, briefly press the scale with
U: -
your foot, press the
user is displayed, and wait 3 seconds. Weigh your-
self again.
The body fat percentage is outside the measurable
BF-Err
range (less than 3% or greater than 65%).
Check the user data or change the activity level.
Diagnostic measurement cannot be taken (e.g.
measurement attempted while wearing shoes). Re-
BF--
peat the measurement barefoot. Otherwise, only
weight values will be displayed and transferred.
The maximum weight capacity of 200 kg has been
Err
exceeded. Loads must not exceed 200 kg.
The batteries are flat. Change the batteries.
Lo
on the rear of
7
on the rear of the device for 5
7
3
settings on your smartphone. Only
®
button
until your scale
4
7.3 Bluetooth
Problem
No Bluetooth
®
connection
Symbol
not displayed
Measurements are
not sent
Symbol
is not
14
on the
displayed
8. DISPOSAL
For environmental reasons, do not dispose of the de-
vice in household waste at the end of its service life.
Dispose of the device at a suitable local collection or
recycling point in your country. Observe the local reg-
ulations for material disposal. Dispose of the device in
accordance with EC Directive – WEEE (Waste Electri-
cal and Electronic Equipment).
If you have any questions, please contact the local
authorities responsible for waste disposal.
You can obtain the location of collection points for old devices from
the local or municipal authorities, local waste disposal company or
your retailer, for example.
The empty, completely flat batteries must be disposed of through
specially designated collection boxes, recycling points or electro-
nics retailers. You are legally required to dispose of the batteries.
The codes below are printed on batteries containing harmful
substances:
Pb = Battery contains lead,
Cd = Battery contains cadmium,
Hg = Battery contains mercury.
12
connection problems
®
Cause / Remedy
Device is outside the Bluetooth
The minimum range in the open is ap-
prox. 10 m. Walls and ceilings reduce the
is
15
range. Other radio waves may interfere
with the transmission. Therefore, do not
position the scale near devices such as
microwaves or induction hobs. Ideally,
switch o other Bluetooth
are within range.
No Bluetooth
connection to the app.
®
Switch on the scale to establish the con-
nection faster.
Switch Bluetooth
®
o and on again. Ensure that the scale is
not being connected via the Bluetooth
settings of the operating system. If nec-
essary, remove it from the device list in
the Bluetooth
settings and then use the
®
"beurer HealthManager Pro" app.
Completely close the app (including in
the background). Switch your smart-
phone o and on again.
Briefly remove the batteries from the
scale and reinsert them. Launch the app.
When connecting the scale, check the
status bar on the smartphone to start
pairing/bonding.
No measurement for the scale user or no
connection.
®
Bluetooth
The user memory (e.g. U: 1) which ap-
pears on the scale display must be as-
signed to the scale in your app settings.
Only these measurements can be trans-
ferred. Therefore, check your user on the
scale when taking a measurement and in
your app settings.
range.
®
devices that
®
on your smartphone
®

Publicité

loading

Ce manuel est également adapté pour:

Bf 915 signature line