F1500-UPS OWNER'S MANUAL
Send Query to UPS: ?BATTERYSTAT<CR>
Action: Load level will be displayed
Response: $BATTERY = xxx<CR>
(xxx is the battery charge level (percentage of maximum charge) expressed in decimal format)
If the value is less than 100, the hundreds digit is represented with a 0.
LIST CONFIGURATION
Requests a list of all configurable parameters and current settings.
Send Query to UPS: ?LIST_CONFIG<CR>
Action: List of configurable parameters and current settings will be displayed
Response: $BTHRESH = level<CR>
$BUZZER = mode<CR>
$AVR = mode<CR>
$FEEDBACK = mode<CR>
$LINEFEED = mode<CR>
$BRIGHTNESS = xxx<CR>
$SCROLL_MODE = xxx<CR>
$SLEEP_MODE = xxx<CR>
VOLTAGE
Requests the input voltage level.
? VOLTAGE (CR)
Response: $ VOLTS-IN = vvv <CR>
(where vvv is the input voltage)
CURRENT
Requests the output current.
? CURRENT (CR)
Response: $ CURRENT = ccc <CR>
(where ccc is the output current in amps)
LIST OF ALL COMMANDS AND QUERIES
Send Query to UPS: ?HELP<CR>
Action: List of all commands and queries will be displayed
Response: !ALL_ON<CR>
!ALL_OFF<CR>
!SWITCH<CR>
!SET_BATTHRESH<CR>
!SET_BUZZER<CR>
!SET_AVR<CR>
!SET_FEEDBACK<CR>
!SET_LINEFEED<CR>
!RESET_ALL<CR>
!SET_BRIGHT<CR>
!SET_SCROLLMODE<CR>
!SET_SLEEPMODE<CR>
?ID<CR> ?OUTLETSTAT<CR>
?POWERSTAT<CR>
?VOLTAGE<CR>
?LOADSTAT<CR>
?BATTERYSTAT<CR>
?LIST_CONFIG<CR>
?HELP<CR>
RESPONSES & MESSAGES
16