IR Power Failure Operation
The F1500-UPS can learn two IR commands. The learned commands will be transmitted on both output jacks so you have the
ability to control 2 different pieces of equipment or use a 2-step macro for one component.
1.
After a power failure and the selected delay, the IR codes will be sent to both outputs. The IR LED's will flash once per
second during the delay time and will stop flashing after the IR code is sent.
2.
If the delay settings are the same for both IR1 and IR2, the IR2 code will be sent to both outputs 2 seconds after IR1.
3.
The IR commands will also be transmitted immediately after the battery charge falls below the critical load battery
threshold. This ensures that equipment will be shutdown properly if the F1500-UPS's load level is extremely high and the
backup time would be less than the selected IR output delay.
4.
There is no IR output after the power is restored to the system.
To program IR output:
1.
From the setup menu, turn the Menu Navigation Knob until IR1 Setup is displayed. Push the Menu Navigation Knob to
select.
2.
Turn the Menu Navigation Knob until IR1 Program is displayed.
3.
The screen will display the message "READY TO SAMPLE REMOTE". Press the button on the remote.
4.
If the signal was learned, then the screen will display the message "IR1 SAMPLED" and advance to the "TEST IR" screen.
Press the navigation knob to test.
5.
If the signal was not learned, the screen will display the message "IR1 SAMPLE FAIL", then it will return to the IR1 Pro
gram screen. Repeat steps 3 and 4.
6.
To program another IR device, from the Setup menu, turn the Menu Navigation Knob until IR2 Setup is displayed. Follow
steps 3-5.
RS-232 Communications Protocol & Command Set
The RS-232 serial interface can be used in the following ways:
1. Initial system setup. An installer can use a notebook computer to set the variables within the Power Control software. Once the
setup is completed, the notebook computer can be disconnected. All settings are stored in the F1500-UPS.
2. Connection to a PC or Network: Functionality is very similar to a standard UPS with a PC. The F1500-UPS can provide contin-
ued power to maintain recording capabilities of any number of devices in the event of a black out or brown out. It is also capable
of saving open documents and shutting down the PC during extended power failures. This requires a permanent RS-232 connec-
tion to the PC and having the Power Control software running in the background on the PC. (Windows based OS only; Mac Energy
Saver software compatible)
3. Integration with sophisticated automation systems like AMX® and Crestron®: The serial communications command set and
protocol is open and is published later in this manual. This information can be used by the automation system programmer for
both F1500-UPS control by the automation system and reporting of power events by the F1500-UPS to the automation system.
Communications Protocol
Connector Pin-out:
Pin 2, Transmit. The F1500-UPS transmits data on this pin.
Pin 3, Receive. The F1500-UPS receives data on this pin.
Pin 5, SG (signal ground).
RS232 Pin-out
1
6
Pin 2 -Transmit
Pin 2 -Transmit
2
7
Pin 3 - Receive
Pin 3 - Receive
3
8
4
9
Pin 5 - Signal Ground
5
1
6
2
7
3
8
4
9
5