5.7 Auto-close ON / OFF
WARNING: To activate the auto-close ON/OFF is required to use additional safety devices
(e.g. photocells).
5.7.1- Press and hold button UP, until it
displays " - " Next the display will show a
number between 0-9, press the buttons UP
or DOWN to adjust auto-close time. Press
button SET to confirm the change.
5.7.3- The default setting is " 0 ", which is auto-close OFF.
5.8 Condominium function
5.8.1 - Press and hold the SET button until the display shows " 5 ". When you release the
button the display shows " 0 " or " 1 ". The default value is " 0 ".
5.8.2 - Press the UP button to change to " 1 " (condominium function activated), press
the DOWN button to change to " 0 " (condominium function deactivated). Press button
SET to confirm.
5.8.3 - Condominium function activated " 1 ".
- During the door opening : if the remote control is pressed the door stops, and if
pressed again, the door will continue to move to the open position. If you press the
remote control again, the door will operate as previously described.
- During the door closing: if the remote control is pressed, the door reverses the
movement (opening direction).
5.8.4 - Condominium function deactivated " 0 ".
- The remote control works normally: open, stop, close, stop.
The condominium function only works when the " 5.6 Photocell " and " 5.7 Auto-close " are
both activated. If one of these functions is desactivated, the door works as if the
condominium function was desactivated.
5.9 Pre-flashing
Press and hold the SET button until the display shows " 7 ". When you release the button
the display shows " 0 " or " 1 ". The default value is " 0 ".
Press the UP button, to change for " 1 " (when you press the remote control, the flash
light will flash, and after 2 seconds the door will move)
Press the DOWN button, to change for " 0 " (The pre-flash function is disabled, when
you press the remote control, the door starts to open). Press button SET to confirm.
LIKE IT
Level Time [sec.] Level
1
10
6
2
20
7
3
30
8
4
40
9
5
50
0
Time [sec.]
60
90
120
180
Auto-close OFF