Télécharger Imprimer la page

TREVIDEA G3 Ferrari AMARCORD Mode D'emploi page 19

Publicité

If you notice formation of limescale, immerse the filters in a solution of water and vinegar and leave to act for
6 hours. Afterwards, wash the filters with dish detergent, rinse and dry.
WARNING: after use, do not leave the filter holder (21) inserted in its seat (13) in order to not damage the
gasket present in the filter holder seat.
With use, impurities and coffee residues may form even in the seat of the filter holder (13).
Periodically check the condition of this part, and if you notice any impurities, proceed with cleaning. Use a
soft sponge, unlock the holes gently with a needle and dispense hot water without mounting the filter holder
(put a large cup underneath and press the 2 cups button, repeat 2 more times).
CAUTION: clean the tube wand only when it is cold.
After each use of the tube (5), dispense steam for a few seconds to clean it of milk residues, and clean the
tube with a damp cloth. At least once a month, clean the parts of the dispenser:
- Remove the tube (5) downwards. Remove the silicone handle (4) by pulling it downwards.
- Clean the internal steam tube with a damp cloth. Periodically clean the tube (5) and handle (4) with a soft
sponge and dish detergent. Rinse and dry well before reassembling them
DECALCIFICATION
Cleaning the coffee machine is necessary to make it work efficiently. Despite this, depending on the water
used and especially if you use hard and calcareous water, it is possible that limescale deposits and impurities
may form, compromising the functionality of the appliance.
In this case it is necessary to descale the internal circuits. To do this, use a specific descaling product for
coffee machines, easily available in specialized shops and service centers. CAUTION: the manufacturer
assumes no responsibility for damage to the machine caused by the use of non-compliant products.
The coffee maker needs decalcification every 3 months:
1. Put a filter in the filter holder and mount it to the docking place without adding the coffee.
2. Fill the container by mixing water and descaler, in the doses indicated in the descaler pack. Fill up to the
MAX level.
3. Place a 250ml container on the grid (15) and press (10 -
4. Empty the container and place it under the steam erogator.
5. Turn the knob (3) and let the hot water flow out for 30 seconds. Wait 5 minutes.
6. Empty the container and repeat steps 3, 4 and 5 until the water in the tank runs out.
At this point it is necessary to rinse the internal circuits to eliminate eventual residues of descaler:
7. Remove the tank (2) and wash it with a soft sponge and dish detergent.
8. Fill the tank with fresh water and put it back on the coffee machine.
9. Place a 250ml container on the grid (15) and press (10 -
10. Empty the container and place it under the steam erogator.
11. Turn the knob (3) and let the hot water flow out for 30 seconds. Empty the container.
The machine is now ready to prepare coffee again.
TROUBLE SHOOTING
Problem
Temperature not correct
Tank is empty / not well inserted
No steam is
generated
Steam nozzle clogged
Coffee runs
Too much powder in the filter and
out around the
filter holder cannot be fixed well
SEAT FOR LINKING THE FILTER HOLDER (13)
STEAM EROGATION TUBE (5)
Cause
).
).
Solution
Wait steam indicator light stop flashing.
Fill the tank / Insert well the tank pressing down
Remove erogation tube (5).
With a needle, remove any encrustations in the
steam outlet hole. If the problem persists, perform
descaling.
Turn off the machine and wait for it cool down,
clean the seat of filter holder as described in
18