General Setting / Allgemeine Einstellungen / Paramètres généraux / Configuración
general / Definição Geral / Algemene instelling / Impostazione generale / Ustawienia
ogólne / Obecné nastavení / Generell inställning / Setare general / Обща настройка
/Generel indstilling / Γενική τοποθέτηση / Üldine seadistus / Yleisasetus / Opće
postavke / Általános beállítás / Bendrasis nustatymas / Vispārīgs iestatījums /
Všeobecné nastavenie / Splošna nastavitev / Genel Ayar / Configuração Geral
Add device (For users who already have the APP account)
Device List
Gateway
Inverter
1
Enter the setting page of EV-Charger
<
Basic information
Charger setting
Advanced setting
2
Check and complete the basic settings of the EV-Charger
<
Activation mode
Dynamic load balance
Modbus Setting
3
Check and complete the advanced settings of the EV-Charger
<
Application scene
Charging phase
Three phase imbalance
Parallel Setting
Random charging delay
Earth_Type
4
Note: The screenshots in this section are taken only as examples. For more details please refer to the user manual.
70
EV Charger
CORE KIT
There are no more
Setting
Charger Setting
Plug&Charge
Advanced setting
1. Turn to the device page following the path [Sites >
Select the exact site from the Site List > Choose EV
Charger from the Device List.
2. Touch the + icon on the right side of the Device List
line and follow the instructions on the App to add the
EV-Charger.
Note: The Registration No. can be found on the
performance label of the EV-Charger.
>
>
>
Follow the path [Sites > Select the exact site from the
Site List > Choose EV Charger from the Device List >
Touch the exact device from the Device List > Setting
button] to enter the setting page and complete the
settings of the EV-Charger as needed.
1)
2)
Disable
3)
70/9600
1. Set the Activation mode (Plug&Charge by
default).
2. Set the Dynamic load balance according to
actual need.
3. If the EV-Charger is connected with Datahub,
Modbus Setting should be done.
Solar
1)
L1
2)
Disable
1. Set the Application scene (Solar by default).
Disable
2. If the EV-Charger is a single-phase one, the
Disable
Charging phase should be set according to the
actual scenario.
TN
3)
3. Check and set the Earth_Type.

Publicité