Télécharger Imprimer la page

Greencut MIG-185 Manuel D'utilisation page 62

Publicité

62
MIG WELDING PARAMETERS
Wire diameter (mm)
0.6
0.8
0.9
1.0
ATMOSPHERE
-
Height above sea level ±1000 M
-
Temperature range during operation ~10~ + 40ºC.
-
Relative air humidity below 90% (20°C).
-
Place the machine on a flat surface or at a maximum angle not exceeding 15°C.
-
Protect the machine from rain and direct sunlight.
-
The content of dust, acid and corrosive gas in the air cannot exceed the normal standard.
-
Ensure that there is sufficient ventilation during the welding process.
-
There must be at least 30 cm distance between the machine and the wall.
USAGE NOTICES
-
Read carefully before using the equipment.
-
Connect the ground wire directly to the equipment.
-
Make sure the input is single-phase: 50/60Hz, 220/230/240V ±10%
-
Non-work related persons should move away from the welding area. Do not look directly at the bow
without protection.
-
Ensure good ventilation to improve the quality of work. Turn off the welder when you are finished using
it to save energy.
-
When the power switch turns off in a protective manner due to a fault, do not reset it until the problem
is resolved.
Welding current (A)
25-110
35-175
45-175
45-175
Plate Thickness (mm)
1.0-1.6
1.0-2.3
1.0-2.3
1.2-6

Publicité

loading