Quick start guide
English
Reference
KT 320
KTT 320
KCC 320
KPA 320
KP320, KP321
Operating temperature, protection of the instruments and information about storage and the battery
•
Operating temperature*: KT320: from -40 to +70 °C; KTT320: from -20 to +70 °C; KCC320,
KPA320, KP320 & KP321: from 0 to 50 °C
•
KT320: IP65; KTT320: IP54; KCC320, KPA320: IP40, KP320, KP321: IP65*
•
Storage temperature: from -20 to +50 °C
Battery power supply: 2 x lithium AA 3.6 V batteries
1
Display
°C: Temperature in °Celsius.
°F: Temperature in °Fahrenheit
%RH: Relative humidity
2
Dimensions (mm)
KT320
*With the pressure connectors plugged
Parameters
Temperature, humidity, current, voltage, electric pulses
Temperature
Temperature, humidity, atmospheric pressure, CO
Temperature, humidity, atmospheric pressure
Differential pressure
DATASET is finished.
END
REC
Indicates that one value is being recorded.
It flashes: the DATASET did not start already.
FULL
Flashing slowly: DATASET is between 80 and 90% of the storage capacity.
Flashing quickly: DATASET is between 90 and 100% of the storage capacity.
Constant: storage capacity full.
BAT
Constant: indicates that the batteries have to be replaced.
1 2
Indicates the channel number which is measuring.
3 4
ACT
Screen actualisation of measured values.
The displayed values are the maximum/minimum values recorded
MIN
MAX
for the channels displayed.
Indication of the direction of exceeding the threshold in the
recorded measurement
KTT320
2
KCC320, KPA320
KP320, KP321