6.3
Tableau Ordres de commande du système
Restore factory setting 0X02
Teach-in
0X02
switching point A
Teach-in
0X02
switching point B
Transfer
0X02
switching points
Teach-in measuring
0X02
range limit A
Teach-in measuring
0X02
range limit B
Transfer
0X02
measuring range
Save parameters
0X02
6.4
Tableau Codes des erreurs
Communication error
(Checksum, ...)
Length of written SPDU is wrong
Reading an unimplemented SPDU
Writing to an unimplemented SPDU
Reading Index 2
Writing to a read only SPDU
Writing an unimplemented System Command
Distance between two tought points too small
Written parameter out of defined range
BA_FADK14IO-Link_V01-02-11_FR.doc
04.12.2012 / ab Version 01-02-11
0X82
Restores all original factory settings of the sensor
0XA0
Teach-in of switching point A. The measured distance is written into the interim switching
points register.
0XA1
Teach-in of switching point B. The measured distance is written into the interim switching
points register.
0XA2
Transfer of the switching points from the interim register to the working register.
0XA3
Teach-in of measuring range limit A. The measured distance is written into the measuring
range interim register
0XA4
Teach-in of measuring range limit B. The measured distance is written into the measuring
range interim register.
0XA5
Transfer of the measuring range from the interim register to the working register
0XE0
Save all parameters in Flash memory
0x10
0x00
0x10
0x00
0x80
0x11
0x80
0x11
0x80
0x23
0x80
0x23
0x80
0x23
0x80
0x40
0x80
0x30
Communication error, No details
Communication error, No details
Device error, Index not available
Device error, Index not available
Device error, Access denied
Device error, Access denied
Device error, Access denied
Device error, Interfering parameter
Device error, Parameter value out of range
16/18
Baumer Electric AG
Frauenfeld, Switzerland