6
Liste SPDUs
Tableau Informations d'ordre général - SPDUs
6.1
General information on sensors
Vendor Name
0X10
Product Name
0X12
Product ID
0X13
Serial Number
0X15
Firmware Revision
0X17
Application Specific
0X18
Name
6.2
Tableau Paramètres SPDUs
Measuring range and switching points
Switching points
0X40
work
Switching points
0X41
interim
Measuring range
0X42
work
Measuring range
0X43
interim
Sensor functions
Average
0X50
Output function
0X62
switching output
Nominal value
0X65
quality parameter
Quality parameter
0X66
BA_FADK14IO-Link_V01-02-11_FR.doc
04.12.2012 / ab Version 01-02-11
18
String
22
String
8
String
4
String
8
String
8
-
4
Switching point A (HB, LB)
Switching point B (HB, LB)
4
Switching point A (HB, LB)
Switching point B (HB, LB)
4
Measuring range limit A (HB, LB)
Measuring range limit B (HB, LB)
4
Measuring range limit A (HB, LB)
Measuring range limit B (HB, LB)
1
-
1
0 = ON, if there is no valid signal
within MB
1 = Switching output defined by
switching points
2 = ON if signal falls below
excess gain signal threshold
1
1
ASCII
R
"Baumer Electric AG" for all sensors
ASCII
R
Corresponds with Baumer article descrip-
tion
ASCII
R
Corresponds with Baumer article number
ASCII
R
Baumer P-Code
ASCII
R
Baumer Firmware Revision
-
R/W
8 Byte at customer disposal
500...4000
R/W
Distance information on switching points
500...4000,
R
Distance information on switching points
65535
500...4000
R/W
Distance information on measuring range
limits
500...4000,
R
Distance information on measuring range
65535
limits
0,1,2,4,8,
R/W
Number of measuring cycles across which
16
it is being averaged.
Average value = 0 or 1: Average is
switched off.
0,1,2
R/W
Indicates what function is available on the
output.
1..8
R/W
Provided the internal quality parameter
drops below this threshold the switching
output is set.
1..8 or 255
R
15/18
Baumer Electric AG